Kueh, Ngee-wei

Behaviour of short piles in soft clay - Bangkok : Asian Institute of Technology, 1980 - 93 p. - Thesis ; no. GT-79-06 . - Asian Institute of Technology. Thesis ; no. GT-79-06 .

A thesis submitted in the partial fulfilment of the requirement for the degree of Master of Engineering, School of Engineering and Technology

Thesis (M.Eng.) - Asian Institute of Technology, 1980

Twenty reinforced concrete piles with a cross-section of 15 cm x 15 cm were constructed for this study. All the piles were 2 m long. They were spliced together at the site to form 4 m and 6 m spliced piles. Three of each group were driven into the ground. Short-term full scale load tests for determination of the failure load were carried out on five spliced-piles. One out of each group was subjected to long-term loading of which the design working load of 1 ton was applied and maintained constant throughout the testing period. Inclination of the spliced piles were measured by the strain-gauges mounted on PVC tubes. Pore water pressure were also measured during and after the driving and found that the excess pore pressure dissipated about 80% of its initial value with 14 days.


Piling (Civil engineering)--Testing