<?xml version="1.0" encoding="UTF-8"?>
<mods xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" version="3.1" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
  <titleInfo>
    <nonSort>A </nonSort>
    <title>study of solar regenerated solid desiccant for air conditioning in a tropical humid climate</title>
  </titleInfo>
  <name type="personal">
    <namePart>Sutavadee Techajunta</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Surapong Chiraratananon</namePart>
    <role>
      <roleTerm type="text">Chairperson</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Exell, R.H.B.</namePart>
    <role>
      <roleTerm type="text">Examination committee</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Bhattacharya, Sribas C.</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Jindal, Vinod Kumar</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Charters, W. W. S.</namePart>
    <role>
      <roleTerm type="text">Examination committee</roleTerm>
    </role>
  </name>
  <name type="corporate">
    <namePart>Royal Thai Government</namePart>
    <role>
      <roleTerm type="text">Scholarship donor</roleTerm>
    </role>
  </name>
  <typeOfResource>text</typeOfResource>
  <genre authority="marc">series</genre>
  <genre authority="marc">technical report</genre>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">th</placeTerm>
    </place>
    <place>
      <placeTerm type="text">Bangkok</placeTerm>
    </place>
    <publisher>Asian Institute of Technology</publisher>
    <dateIssued>1999</dateIssued>
    <issuance>continuing</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <extent>195 leaves</extent>
  </physicalDescription>
  <abstract>Air-conditioning for comfort has penetrated widely in tropical climates. Most air conditioning systems use conventional refrigerants and are based on a vapor-compression  cycle. However, most such refrigerants are harmful to the atmosphere and the systems  consume high levels of electricity. As a result, solar-power vapor absorption cycle air conditioning received brief interest over a decade ago, but the system is complicated and  difficult to maintain.  Solid-desiccant based adsorbent systems for dehumidification and cooling have  received attention because the systems are less complicated and because such systems can  utilize solar energy or other renewable energy. Most of the studies involving such systems so  far have been based on an indirect application of solar energy.  This dissertation reports on a study into the use of silica gel, a solid desiccant, in  systems incorporating a desiccant panel for dehumidification and cooling of air for air conditioning. The desiccant panel is regenerated directly by solar radiation.  'The first part of the work comprises a study on desiccant regeneration in the laboratory  using a solar simulator to examine the effects of insolation and air flow rate on the  performance of the system. The results indicate that the regeneration rate is influenced more  by insolation than air flow rate, especially for insolation above 400 W/m2 {u2022} A mathematical  model was compiled to calculate the temperature and humidity of the air exiting from the  desiccant panel. Results of the calculations from the model agree well with experimental  results. The mathematical model was also applied to study other effects that were not carried  out in the laboratory such as the temperature and the moisture content of the inlet air, moisture  content in silica gel, etc. The results from the mathematical model also clarify the relative  influence of air flow rate and solar insolation.  An air-dehumidification study in the laboratory is included to examine various factors  influencing the performance of the system. The results from the experiment indicate that the  adsorption rate increases with a higher air flow rate. However, the adsorption rate could. be  reduced if solar radiation is applied. The mathematical model developed was applied to  calculate the temperature and the moisture content. of the air from the desiccant panel. All  calculation results agree well with the experimental results.  A system of solar-regenerated desiccant dehumidification was devised. During the day  time, the desiccant system is disconnected from the space to be conditioned and the  regeneration of the desiccant is achieved through solar heating. During the night, ventilation  air is passed through a set of regenerated desiccant panels. The warm air exiting from the  panels is cooled by cool water in a water-air heat exchanger. After the water is used to cool  the wa1m air, it is itself cooled in the cooling tower. Known mathematical models of heat  exchangers and cooling towers were used with the model for the desiccant panels. The  combined desiccant dehumidification model was then used to calculate the condition of the  ventilation air through the system. Temperature, relative humidity and other weather data for  Bangkok, Thailand in 1985 was used in a simulation study.  lll In this desiccant assisted air-conditioning (DAAC) system study, the desiccant panels  and its cooling system formed a desiccant dehumidification system to dehumidify the  ventilation air which is supplied to a bedroom. The dehumidified air is mixed with the return  air from the room and then cooled by a conventional air-conditioner and supplied into the  bedroom at night. The simulation results indicate that the DAAC system is able to remove  substantial moisture from the ventilation air. A total reduction of 36% of the load at the  cooling coil results.  Another system of desiccant air-conditioning was devised. This larger system was  used to dehumidify the supply air for the same bedroom. The dehumidified air was  evaporatively cooled and supplied to the bedroom. Simulation calculations using the  aforementioned weather data indicates that the system can replace a conventional air conditioning system. In terms of thermal comfort, or thermal neutrality, the system could  achieve the same level of acceptance of comfort as that from a conventional system.  In both cases of the simulation study, the results indicate that solar-regenerated  desiccant systems can be used to achieve acceptable levels of thermal comfort, but also use  lower amounts of electricity.</abstract>
  <note>A dissertation submitted in partial fulfillment of the requirements for the degree of Doctor  of Engineering, School of Environment, Resources and Development</note>
  <note>Thesis (Ph.D.) - Asian Institute of Technology, 1999</note>
  <subject authority="lcsh">
    <topic>Air conditioning</topic>
  </subject>
  <subject authority="lcsh">
    <topic>Drying agents</topic>
  </subject>
  <subject authority="lcsh">
    <topic>Silica gel</topic>
  </subject>
  <relatedItem type="series">
    <titleInfo>
      <title>Dissertation. no. ET-99-02</title>
    </titleInfo>
    <name type="corporate">
      <namePart>Asian Institute of Technology.</namePart>
      <namePart/>
    </name>
  </relatedItem>
  <identifier type="uri">http://203.159.5.9/ait-thesis/detail.php?q=B11871</identifier>
  <location>
    <url displayLabel="Full-Text">http://203.159.5.9/ait-thesis/detail.php?q=B11871</url>
  </location>
  <recordInfo>
    <recordCreationDate encoding="marc">290900</recordCreationDate>
    <recordChangeDate encoding="iso8601">20260818223126.0</recordChangeDate>
  </recordInfo>
</mods>