    <title>Testing of manually operated coiled tube pump</title>
  </titleInfo>
  <name type="personal">
    <namePart>Basunia, Mohammad Ali</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Gee-Clough, D.</namePart>
    <role>
      <roleTerm type="text">Chairperson</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Singh, Gajendra</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Gupta, Chandra P.</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Salokhe, Vilas M.</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <name type="corporate">
    <namePart>The Royal Government of Netherland</namePart>
    <role>
      <roleTerm type="text">Scholarship Donor</roleTerm>
    </role>
  </name>
  <typeOfResource>text</typeOfResource>
  <genre authority="marc">series</genre>
  <genre authority="marc">technical report</genre>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">th</placeTerm>
    </place>
    <place>
      <placeTerm type="text">Bangkok</placeTerm>
    </place>
    <publisher>Asian Institute of Technology</publisher>
    <dateIssued>1989</dateIssued>
    <issuance>continuing</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <extent>122 p.</extent>
  </physicalDescription>
  <abstract>The performance of a coil tube pump modified in AIT was  evaluated both by variable speed motor and by manually. Maximum  lift was found to b e 275 cm by using 1 2 turns in the coil.  Suitable rpm for manual operation was found to be in between 35  to 25 rpm and within this speed range a labor can operate this  pump continuous l y for 45 to 60 minutes. For lift 100-275 cm power  requirement for 30 rpm was 16-72 watt and maximum discharge and  efficiency were found to be 58 litre/min . and 60 % respectively .  For this speed , the optimum angle of operation was found to be 24  degree (7 5 % diameter coil submergence ).  Keeping average input power 30 watt (arms/ shoulder) a nd 75  watt (pedaling ) fixed cu t off points at different lifts were  calculated. Best cu t - off point for 30 watt and 75 watt occurred at  25 rpm a nd 48 rpm at lift 24 0 cm and 250 cm at which efficiency  was 61% and 45 % respectively.  The overall performance of the coil tube pump is good. So  there is a need to popularize this pump suitable for supplying  irrigation water to vegetables, rice and wheat fields in the non-industrialized countries. </abstract>
  <note>A thesis submitted in partial fulfillment of the requirements  for the degree of Master of Engineering, School of Environment, Resources and Development</note>
  <note>Thesis (M.Eng.) - Asian Institute of Technology, 1989</note>
  <subject authority="lcsh">
    <topic>Pumping machinery</topic>
    <topic>Testing</topic>
  </subject>
  <relatedItem type="series">
    <titleInfo>
      <title>Thesis ; no. AE-89-06</title>
    </titleInfo>
    <name type="corporate">
      <namePart>Asian Institute of Technology.</namePart>
      <namePart/>
    </name>
  </relatedItem>
  <identifier type="uri">http://203.159.5.9/ait-thesis/detail.php?q=B17818</identifier>