<?xml version="1.0" encoding="UTF-8"?>
<mods xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" version="3.1" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
  <titleInfo>
    <title>Thermal diffusion in an estuary</title>
  </titleInfo>
  <name type="personal">
    <namePart>Tseng, Wen-huei</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Prida Thimakorn</namePart>
    <role>
      <roleTerm type="text">Chairperson</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Suphat Vongvisessomjai</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Abe, Tetsuo</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <name type="corporate">
    <namePart>Government of the Republic of China</namePart>
    <role>
      <roleTerm type="text">Scholarship Donor</roleTerm>
    </role>
  </name>
  <typeOfResource>text</typeOfResource>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">th</placeTerm>
    </place>
    <place>
      <placeTerm type="text">Bangkok</placeTerm>
    </place>
    <publisher>Asian Institute of Technology</publisher>
    <dateIssued>1981</dateIssued>
    <issuance>monographic</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <form authority="marcform">print</form>
    <extent>v, 80 p.</extent>
  </physicalDescription>
  <abstract>The warm water issuing from the 2,400 MW Bang Pakong Power Plant was investigated in the vicinity of the plant site under unsteady flow condition in a hydraulic model .  Heat distribution in the far field and warm water recirculation to the pump intake were obtained. Reproduction of unsteady flow was made by a built-in tide generator, and the warm water generator distributed the  pre-determined temperature to the outfall structure.  Temperature distribution and warm water circulation due to the depression of outfall structure were also conducted. It was found that there was an  effective temperature reduction due to lowering the elevation of outfall structure.</abstract>
  <note>A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Engineering and Technology</note>
  <note>Thesis (M.Eng.) - Asian Institute of Technology, 1981</note>
  <subject authority="lcsh">
    <topic>Thermal pollution of rivers, lakes, etc</topic>
  </subject>
  <subject authority="lcsh">
    <topic>Thermal diffusivity</topic>
  </subject>
  <relatedItem type="series">
    <titleInfo>
      <title>Thesis ; no. WA-80-18</title>
    </titleInfo>
    <name type="corporate">
      <namePart>Asian Institute of Technology.</namePart>
      <namePart/>
    </name>
  </relatedItem>
  <identifier type="uri">http://203.159.5.9/ait-thesis/detail.php?q=B21797</identifier>
  <location>
    <url displayLabel="Full-Text">http://203.159.5.9/ait-thesis/detail.php?q=B21797</url>
  </location>
  <recordInfo>
    <recordCreationDate encoding="marc">130598</recordCreationDate>
    <recordChangeDate encoding="iso8601">20260819084508.0</recordChangeDate>
  </recordInfo>
</mods>