    <title>Treatment of domestic wastewater with chemical precipitation</title>
  </titleInfo>
  <name type="personal">
    <namePart>Anchalee Natikool</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Samorn Muttamara</namePart>
    <role>
      <roleTerm type="text">Chairperson</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Chongrak Polprasert</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Ha, Sung Ryong</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <name type="corporate">
    <namePart>Electricity Generating Authority of Thailand</namePart>
    <role>
      <roleTerm type="text">Scholarship Donor</roleTerm>
    </role>
  </name>
  <typeOfResource>text</typeOfResource>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">th</placeTerm>
    </place>
    <place>
      <placeTerm type="text">Bangkok</placeTerm>
    </place>
    <publisher>Asian Institute of Technology</publisher>
    <dateIssued>1997</dateIssued>
    <issuance>monographic</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <form authority="marcform">print</form>
    <extent>71 leaves</extent>
  </physicalDescription>
  <abstract>A thesis submitted in partial fulfillment of the requirements for the degree of Master of  Science, School of Environment, Resources and Development </abstract>
  <abstract>This study investigates the feasibility for the operation of domestic wastewater  treatment by chemical precipitation. In this study AIT wastewater was employed as a  domestic wastewater being treated. Three coagulants which are ferric chloride,  polyaluminium chloride and ferric sulfate were employed as a coagulants. Jar test which was  used to determine the optimum coagulant dosage and pH results that the most appropriate  coagulant, among above three coagulants, for applying with AIT wastewater treatment is  fenic chloride. The optimum dosage and pH of ferric chloride are 400 mg/l and 8.0  respectively.  By applying ferric chloride as a coagulant for AIT wastewater treatment through a  chemical precipitation, it is found that the effluent concentration are met requirement of the  DEG. The effluent concentration and the removal efficiency for removal of BOD, TSS, TDS,  Org-N and TP, which are 16 mg/l, 4 mg/l, 15 mg/l, 4 mg/l, and 0.4 mg/l respectively, and  70%, 89%, 32%, 33% and 80% respectively, can be achieved through chemical treatment  system. From comparison between chemical treatment process and biological treatment  process, it is interesting to indicate that the chemical treatment process has more advantages  over the biological treatment process.  As above it can be indicated that chemical wastewater treatment is an acceptable  method for domestic wastewater treatment, and can replace the conventional biological  treatment system.</abstract>
  <note>Thesis (M.Sc.) - Asian Institute of Technology, 1997</note>
  <subject authority="lcsh">
    <topic>Sewage</topic>
    <topic>Purification</topic>
    <topic>Precipitation</topic>
  </subject>
  <relatedItem type="series">
    <titleInfo>
      <title>Thesis ; no. EV-97-03</title>
    </titleInfo>
    <name type="corporate">
      <namePart>Asian Institute of Technology.</namePart>
      <namePart/>
    </name>
  </relatedItem>
  <identifier type="uri">http://203.159.5.9/ait-thesis/detail.php?q=B14290</identifier>
  <location>
    <url displayLabel="Full-Text">http://203.159.5.9/ait-thesis/detail.php?q=B14290</url>
  </location>
  <recordInfo>
    <recordCreationDate encoding="marc">      </recordCreationDate>
    <recordChangeDate encoding="iso8601">20260819085207.0</recordChangeDate>
  </recordInfo>
</mods>