    <title>Calibration and performance evaluation of a vane-in-a-pipe : a water measuring device for partly filled pipes</title>
  </titleInfo>
  <name type="personal">
    <namePart>Butlig, Felipe Tancio</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Apichart Anukularmphai</namePart>
    <role>
      <roleTerm type="text">Chairperson</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Prida Thimakorn</namePart>
    <role>
      <roleTerm type="text">Co-Chairperson</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Olesen, Svend Elsnab</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <name type="corporate">
    <namePart>Government of Australia</namePart>
    <role>
      <roleTerm type="text">Scholarship Donor</roleTerm>
    </role>
  </name>
  <typeOfResource>text</typeOfResource>
  <genre authority="marc">series</genre>
  <genre authority="marc">technical report</genre>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">th</placeTerm>
    </place>
    <place>
      <placeTerm type="text">Bangkok</placeTerm>
    </place>
    <publisher>Asian Institute of Technology</publisher>
    <dateIssued>1981</dateIssued>
    <issuance>continuing</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <extent>69 p.</extent>
  </physicalDescription>
  <abstract>Three sizes of the vane-in-a-pipe flow measuring device (VIP) were tested at the Hydraulics laboratory of the Asian Institute of Technology. The sizes of VIP tested were 25.4 cm, 30.5 cm, and 38.1 cm, each having a length of 100 cm. These are equivalent to the standard sizes of reinforced concrete pipes (culverts) available in the market. Results of the study showed that the approach and exit flow conditions did not significantly affect the discharge through the device. Likewise,  the variations of submergence ratios, did not significantly affect the discharge. Furthermore, discharges calculated using the theoretical equations of the three sizes of VIP did not significantly differ from the discharges calculated using the set of statistically derived discharge equations. All these parameters were tested at the 95% confidence interval as recommended by the International Standards Organization (ISO). Another significant result of the study showed the independence of the moment to variations in velocity  for a given discharge. The VIP device is suitable in measuring flow with low velocity and flat gradient channels. It is not suggested as a blanket replacement for other flow measuring devices. Instead, it could serve as a valuable addition to the researchers list of tools complementing the traditional weirs and flumes.</abstract>
  <note>A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Environment, Resources and Development</note>
  <note>Thesis (M.Eng.) - Asian Institute of Technology, 1981</note>
  <subject authority="lcsh">
    <topic>Flow meters</topic>
    <topic>Calibration</topic>
  </subject>
  <relatedItem type="series">
    <titleInfo>
      <title>Thesis ; no. AE-81-04</title>
    </titleInfo>
    <name type="corporate">
      <namePart>Asian Institute of Technology.</namePart>
      <namePart/>
    </name>
  </relatedItem>
  <identifier type="uri">http://203.159.5.9/ait-thesis/detail.php?q=B21507</identifier>
  <location>
    <url displayLabel="Full-Text">http://203.159.5.9/ait-thesis/detail.php?q=B21507</url>
  </location>
  <recordInfo>
    <recordCreationDate encoding="marc">230998</recordCreationDate>
    <recordChangeDate encoding="iso8601">20260817172058.0</recordChangeDate>
  </recordInfo>
</mods>