    <title>Chromium removal in anaerobic filter and rotating biological contactor processes</title>
  </titleInfo>
  <name type="personal">
    <namePart>Prayitno</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>K.  Udornsinrot</namePart>
    <role>
      <roleTerm type="text">Chairperson</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Vigneswaran, Saravanamuthu</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Tran, Francis T.</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <name type="corporate">
    <namePart>USAID - Indonesian GPT II Project</namePart>
    <role>
      <roleTerm type="text">Scholarship Donor</roleTerm>
    </role>
  </name>
  <typeOfResource>text</typeOfResource>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">th</placeTerm>
    </place>
    <place>
      <placeTerm type="text">Bangkok</placeTerm>
    </place>
    <publisher>Asian Institute of Technology</publisher>
    <dateIssued>1989</dateIssued>
    <issuance>monographic</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <extent>65 p.</extent>
  </physicalDescription>
  <abstract>A combination of anaerobic filter and rotating biological  contactor system at laboratory scale was operated as one unit  system to treat synthetic wastewater containing chromium.  The soluble COD concentration of wastewater was varied at  about 2000, 1400, and 800 mg/1. The combination system was  operated at constant detention time, it was 4 hours in the AF  unit and 20 hours in the RBC unit, resulting in organic loading  rate of 2.02, 1.41 and 0.77 kg SCOD/m3 /d for the whole system or  12.31, 7.99 and 4.67 kg SCOD/m3/d for the anaerobic filter  system.  No significant differences on the organic carbon removal by  varying the organic loading rate with chromium concentration of  5 mg/1 in wastewater. The removal efficiency of soluble COD was  97, 98, and 96 % and chromium removal efficiency was 98, 99, and  98 % for organic loading rate of 2.02, 1.41,and 0.77 kg SCOD/m3 /d  respectively.  Increasing chromium concentration up to 10 mg/l at organic  loading rate of 0.81 kg SCOD/m3 /d was not influenced in SCOD  removal as well as chromium removal efficiency.  The combination of the anaerobic filter and rotating  biological contactor was found to be effective and have a good  performance for treating organic wastewater containing chromium  in the wide range of organic loading.  Half saturation constants in this system were 14.67 and  1000 mg/l for rotating biological contactor and anaerobic filter  respectively.</abstract>
  <note>A thesis submitted in partial fulfillment of the requirements for  the degree of Master of Science, School of Environment, Resources and Development </note>
  <note>Thesis (M.Sc.) - Asian Institute of Tehcnology, 1989</note>
  <subject authority="lcsh">
    <topic>Sewage</topic>
    <topic>Purification</topic>
    <topic>Chromium removal</topic>
  </subject>
  <relatedItem type="series">
    <titleInfo>
      <title>Thesis ; no. EV-89-14</title>
    </titleInfo>
    <name type="corporate">
      <namePart>Asian Institute of Technology.</namePart>
      <namePart/>
    </name>
  </relatedItem>
  <identifier type="uri">http://203.159.5.9/ait-thesis/detail.php?q=B18013</identifier>
  <location>
    <url displayLabel="Full-Text">http://203.159.5.9/ait-thesis/detail.php?q=B18013</url>
  </location>
  <recordInfo>
    <recordCreationDate encoding="marc">120399</recordCreationDate>
    <recordChangeDate encoding="iso8601">20260817172714.0</recordChangeDate>
  </recordInfo>
</mods>