<?xml version="1.0" encoding="UTF-8"?>
<mods xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" version="3.1" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
  <titleInfo>
    <title>Construction of an original test bed for evaluating solar collector performance non-linearly</title>
  </titleInfo>
  <name type="personal">
    <namePart>Sompan Poolpol</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Saunier, G.Y.</namePart>
    <role>
      <roleTerm type="text">Chairperson</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Follea, D.</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Exell, Robert H.B.</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <name type="corporate">
    <namePart>USAID- ASEAN</namePart>
    <role>
      <roleTerm type="text">Scholarship Donor</roleTerm>
    </role>
  </name>
  <typeOfResource>text</typeOfResource>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">th</placeTerm>
    </place>
    <place>
      <placeTerm type="text">Bangkok</placeTerm>
    </place>
    <publisher>Asian Institute of Technology</publisher>
    <dateIssued>1981</dateIssued>
    <issuance>monographic</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <form authority="marcform">print</form>
    <extent>xi, 55 p.</extent>
  </physicalDescription>
  <abstract>Testing of solar collectors following the standard methods is time consuming . The performance of the collector resulted from data assessment  through linear regression method providing by t he manufacture is not correct if the working conditions are different from the test conditions. Professor G.Y. Saunier has proposed his non- linear model applied to any working  condition. Two test beds were constructed in order to determine t he intrinsic parameters needed . Three kinds of commercial collectors were  tested and the error of the results and instruments used were analyzed statistically. It was shown that the accuracy of differential temperature  measuring device was not high enough so that the large error happened at low water temperature . The new method of determing back and side loss  coefficient of the collector was suggested and some problems in t he experimental work were discussed. </abstract>
  <note>A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Environment, Resources and Development</note>
  <note>Thesis (M.Eng.) - Asian Institute of Technology, 1981</note>
  <subject authority="lcsh">
    <topic>Solar collectors</topic>
    <topic>Testing</topic>
  </subject>
  <relatedItem type="series">
    <titleInfo>
      <title>Thesis ; no. ET-81-11</title>
    </titleInfo>
    <name type="corporate">
      <namePart>Asian Institute of Technology.</namePart>
      <namePart/>
    </name>
  </relatedItem>
  <identifier type="uri">http://203.159.5.9/ait-thesis/detail.php?q=B21579</identifier>
  <location>
    <url displayLabel="Full-Text">http://203.159.5.9/ait-thesis/detail.php?q=B21579</url>
  </location>
  <recordInfo>
    <recordCreationDate encoding="marc">080998</recordCreationDate>
    <recordChangeDate encoding="iso8601">20260818084920.0</recordChangeDate>
  </recordInfo>
</mods>