Bamayi, Wladimir Askinin

Design criteria development of rotating biological contactor and anaerobic (upflow) filter system for sewage treatment - Bangkok : Asian Institute of Technology, 1983 - 57 leaves : ill. - Thesis ; no. EV-83-4 . - Asian Institute of Technology. Thesis ; no. EV-83-4 .

A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering

Thesis (M.Eng.) - Asian Institute of Technology

The study is performed to find a suitable low cost system for the treat- ment of domestic sewage. The possibility of using anaerobic filter, rotating biological disk and their combination was studied. From the anaerobic filter performance at varying hydraulic loading rates (1.41, 1.764, 2.45 m3/m2.d), it was found that beyond a hydraulic loading rate of 1.764 m3/m2.d, the COD removal efficiency was not satisfactory. The filter depth of 120 cm (2-2.5 cm broken stone) was necessary to achieve a reasonable COD removal. The RBC performance at different hydraulic loading rates (0.03, 0.06 and 0.12 m3/m2·d) indicated that the removal efficiency lies in a range of 72 to 82%. The detailed capital and operational and maintenance cost calculation also favour the RBC compared to the AF and the combination of RBC and AF.


Water--Purification--Filtration
Filters and filtration