<?xml version="1.0" encoding="UTF-8"?>
<mods xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" version="3.1" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
  <titleInfo>
    <title>Design parameters of completely mixed aerated lagoon in the tropics</title>
  </titleInfo>
  <name type="personal">
    <namePart>Wichien Tangthai</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Yang, Ping Yi</namePart>
    <role>
      <roleTerm type="text">Chairperson</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Pescod, M.B.</namePart>
    <role>
      <roleTerm type="text">Co-Chairperson</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Samorn Muttamara</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <typeOfResource>text</typeOfResource>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">th</placeTerm>
    </place>
    <place>
      <placeTerm type="text">Bangkok</placeTerm>
    </place>
    <publisher>Asian Institute of Technology</publisher>
    <dateIssued>1976</dateIssued>
    <issuance>monographic</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <form authority="marcform">print</form>
    <extent>65 p.</extent>
  </physicalDescription>
  <abstract>This study includes the application of more fundamental concepts on the design parameters of aerated lagoon for the treatment of industrial  wastewaters. The pulp (from Bang Pa-In Paper Mill), synthetic fiber and dyeing finishing (from Asia Fibre Factory) wastewaters have been used as the carbon source. The temperature lies between 25 to 30°C. The lab scale aerated lagoons, surface aeration type are used. The design parameters of Eckenfelder's approach includes, namely, substrate removal rate coefficient (k), mass yield rate (a), endogenous respiration rate coefficient (b) synthesis oxygen demand rate (a) and  endogenous respiration oxygen demand rate (b'). All parameters were evaluated and discussed. They also were compared with those investigated by previous works performed at 20°c to see the temperature effect. The  effect of wastewater characteristics on the value of these parameter were  discussed. All values of parameters obtained in different wastes were compared together.</abstract>
  <note>A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering of the Asian Institute of Technology, Bangkok, Thailand.</note>
  <note>Thesis (M.Eng.) - Asian Institute of Technology, 1976</note>
  <subject authority="lcsh">
    <topic>Water treatment plants</topic>
  </subject>
  <subject authority="lcsh">
    <topic>Water</topic>
    <topic>Pollution</topic>
  </subject>
  <subject authority="lcsh">
    <topic>Factory and trade waste</topic>
  </subject>
  <relatedItem type="series">
    <titleInfo>
      <title>Thesis ; no. 886</title>
    </titleInfo>
    <name type="corporate">
      <namePart>Asian Institute of Technology.</namePart>
      <namePart/>
    </name>
  </relatedItem>
  <identifier type="uri">http://203.159.5.9/ait-thesis/detail.php?q=B23701</identifier>
  <location>
    <url displayLabel="Full-Text">http://203.159.5.9/ait-thesis/detail.php?q=B23701</url>
  </location>
  <recordInfo>
    <recordCreationDate encoding="marc">140198</recordCreationDate>
    <recordChangeDate encoding="iso8601">20260818090310.0</recordChangeDate>
  </recordInfo>
</mods>