<?xml version="1.0" encoding="UTF-8"?>
<mods xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" version="3.1" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
  <titleInfo>
    <title>Determination of optimal microwave curing process to obtain the highest early strength of normal concrete</title>
  </titleInfo>
  <name type="personal">
    <namePart>Nawaz, Adnan</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Pennung Warnitchai</namePart>
    <role>
      <roleTerm type="text">Chairperson</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Thanakorn Pheeraphan</namePart>
    <role>
      <roleTerm type="text">Co-Chairperson</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Raktipong Sahamitmongkol</namePart>
    <role>
      <roleTerm type="text">Examination committee</roleTerm>
    </role>
  </name>
  <name type="corporate">
    <namePart>HEC, Pakistan</namePart>
    <role>
      <roleTerm type="text">Scholarship donor</roleTerm>
    </role>
  </name>
  <typeOfResource>text</typeOfResource>
  <genre authority="marc">series</genre>
  <genre authority="marc">technical report</genre>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">th</placeTerm>
    </place>
    <place>
      <placeTerm type="text">Pathum Thani, Thailand</placeTerm>
    </place>
    <publisher>Asian Institute of Technology</publisher>
    <dateIssued>2010</dateIssued>
    <issuance>continuing</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <extent>63 leaves : ill.</extent>
  </physicalDescription>
  <abstract>In this research study, an effort has been made to determine an optimum  curing  process that can  give us the highest early compressive strength of normal concrete using microwave energy. The  optimal  microwave  curing  process  is  determined  to  attain  the  highest  early  strength  of  normal  concrete.  The  optimal  microwave  cur ing  process  includes  the  determination  of  amount  of  microwave  power  output  for  different  levels,  time  interval  between  different  microwave  power  levels and the time  interval  between the  microwave curing and the compressive  strength test. A  series of experi ments are carried out using trial and  error  method to achieve the optimal curing  process.  The  consequential  process  can  turn  out  50 - 60%  of  7  days  compressive  strength  of  normally  cured  concrete  within  10.5  hours  after  mixing. After  obtaining  the  optimal  cu ring  process   for   normal  concrete,   same procedure is applied   on   concrete  mixes   of   different  compositions,  containing  fly  ash  in  different  amounts,  for  comparison.  The  outcome  illustrates  that the optimum curing process worked out is not only valid for the n ormal concrete but also for  the concrete containing fly ash as a replacement of cement content. </abstract>
  <note>Submitted in partial fulfillment of the requirements for the Degree of Master of Engineering in Structural Engineering, School of Engineering and Technology</note>
  <note>Research report (M. BA.) - Asian Institute of Technology, 2010</note>
  <subject authority="lcsh">
    <topic>Concrete</topic>
    <topic>Curing</topic>
  </subject>
  <subject authority="lcsh">
    <topic>Microwage heating</topic>
  </subject>
  <relatedItem type="series">
    <titleInfo>
      <title>Research studies project report ; no. ST-10-03</title>
    </titleInfo>
    <name type="corporate">
      <namePart>Asian Institute of Technology.</namePart>
      <namePart/>
    </name>
  </relatedItem>
  <identifier type="uri">http://203.159.5.9/ait-thesis/detail.php?q=B01661</identifier>
  <location>
    <url displayLabel="Full-Text">http://203.159.5.9/ait-thesis/detail.php?q=B01661</url>
  </location>
  <recordInfo>
    <recordCreationDate encoding="marc">110314</recordCreationDate>
    <recordChangeDate encoding="iso8601">20260818090423.0</recordChangeDate>
  </recordInfo>
</mods>