<?xml version="1.0" encoding="UTF-8"?>
<mods xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" version="3.1" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
  <titleInfo>
    <title>Development of a glazed reversed flat plate collector with slim reflectors</title>
  </titleInfo>
  <name type="personal">
    <namePart>Wei, Xuening</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Prida Wibulswas</namePart>
    <role>
      <roleTerm type="text">Chairpeson</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Mora, Jean-Claude</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Lasnier, France</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <typeOfResource>text</typeOfResource>
  <genre authority="marc">series</genre>
  <genre authority="marc">technical report</genre>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">th</placeTerm>
    </place>
    <place>
      <placeTerm type="text">Bangkok</placeTerm>
    </place>
    <publisher>Asian Institute of Technology</publisher>
    <dateIssued>1987</dateIssued>
    <issuance>continuing</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <extent>62 p.</extent>
  </physicalDescription>
  <abstract>The performance of a reversed flat plate collector with a  single glass cover and insulation underneath its slim  reflectors and a hot water system has bee n investigated. The  reflectors were made of stainless steel. Testing was carried  out on sunny days only. The collector efficiency test was  conducted by means of ASHRAE method on the solar testing bed  at AIT energy park. Results from the experiments show that  the collector efficiency of present design is higher than  that of Das'design and lower than that of Lim's des ign. The  experiments of system efficiency were performed by connecting  to a storage tank. Through the results of testing, a graph of  the system efficiency is obtained. It is used for conducting  economic assessment. The slope of the present performance curve  is about 0.3, which is slightly lower than that of previous  RFPC To analyse the economic viability of this Reversed  Flat Plate Collector, the annual saving of the system a nd the  cost of useful energy have been investigated. Results s how  that if the useful life is 15 or more y ears, the system of this  RFPC will be economically feasible. The results compare d with a  previous design show that the present design , is more .  economical.  Further study and improvement of the Re versed Flat Plate  collector are recommended . </abstract>
  <note>A research study (12 credits) submitted in partial fulfillment of the requirement for the degree of Master of Engineering, School of Environment, Resources and Development</note>
  <note>Research Studies Project Report (M. Eng..) - Asian Institute of Technology, 1987</note>
  <subject authority="lcsh">
    <topic>Solar collectors</topic>
  </subject>
  <relatedItem type="series">
    <titleInfo>
      <title>Research studies project report ; no. ET-87-18</title>
    </titleInfo>
    <name type="corporate">
      <namePart>Asian Institute of Technology.</namePart>
      <namePart/>
    </name>
  </relatedItem>
  <identifier type="uri">http://203.159.5.9/ait-thesis/detail.php?q=B19003</identifier>
  <location>
    <url displayLabel="Full-Text">http://203.159.5.9/ait-thesis/detail.php?q=B19003</url>
  </location>
  <recordInfo>
    <recordCreationDate encoding="marc">261198</recordCreationDate>
    <recordChangeDate encoding="iso8601">20260818090644.0</recordChangeDate>
  </recordInfo>
</mods>