<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>02054nas a2200313 a 4500</leader>
  <controlfield tag="005">20260818090847.0</controlfield>
  <controlfield tag="008">230830s2012    th a   |||    000   eng d</controlfield>
  <datafield tag="035" ind1=" " ind2=" ">
    <subfield code="a">.b1241153x</subfield>
  </datafield>
  <datafield tag="100" ind1="0" ind2=" ">
    <subfield code="a">Charusluk Viphavakit</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
    <subfield code="a">Development of integrated optical characterization bench for sensing Microfluidic channel </subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a">Pathum Thani :</subfield>
    <subfield code="b">Asian Institute of Technology,</subfield>
    <subfield code="c">2012</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">60 leaves :</subfield>
    <subfield code="b">ill.</subfield>
  </datafield>
  <datafield tag="502" ind1=" " ind2=" ">
    <subfield code="a">Thesis (M. Eng.) - Asian Institute of Technology, 2012</subfield>
  </datafield>
  <datafield tag="500" ind1=" " ind2=" ">
    <subfield code="a">A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering in Nanotechnology</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">This work introduces design, fabrication and characterization of an optical based integrated flow rate sensor where the light- fluid interaction is maximized by allowing the liquid and light to propagate along the same direction. This is achieved by placing a 10 {uF06D}m deep channel between two waveguides. The optical waveguides are tapered down to the channel width to feed the light in and out, where tapering is done to minimize the coupling and propagation loss. The output signal is detected by a fast receiver (higher than 1MHz) that records the dynamic change of the light intensity when fluid flows through the channel. This scheme allows for the direct measurement of the liquid flow rate with higher interaction length between fluid and light. The initial results showed a dynamic range of measurement up to 0.18.</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Microfluidic devices</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Optical Devices</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Integrated optics</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Dutta, Joydeep,</subfield>
    <subfield code="e">Chairperson</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Mohammed, Waleed S.,</subfield>
    <subfield code="e">Examination committee</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Hornyak, Gabor L.,</subfield>
    <subfield code="e">Examination committee</subfield>
  </datafield>
  <datafield tag="700" ind1="0" ind2=" ">
    <subfield code="a">Poompat Saengudomlert,</subfield>
    <subfield code="e">Examination Committee</subfield>
  </datafield>
  <datafield tag="710" ind1="2" ind2=" ">
    <subfield code="a">Royal Thai Government Fellowship</subfield>
    <subfield code="e">Scholarship Donor</subfield>
  </datafield>
  <datafield tag="856" ind1=" " ind2=" ">
    <subfield code="3">Full-Text</subfield>
    <subfield code="u">http://203.159.5.9/ait-thesis/detail.php?q=B05138</subfield>
  </datafield>
  <datafield tag="907" ind1=" " ind2=" ">
    <subfield code="a">.b1241153x</subfield>
    <subfield code="b">mnait</subfield>
    <subfield code="c">m</subfield>
  </datafield>
  <datafield tag="902" ind1=" " ind2=" ">
    <subfield code="a">240419</subfield>
  </datafield>
  <datafield tag="998" ind1=" " ind2=" ">
    <subfield code="b">0</subfield>
    <subfield code="c">230830</subfield>
    <subfield code="d">m</subfield>
    <subfield code="e">a  </subfield>
    <subfield code="f">m</subfield>
    <subfield code="g">0</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">29355</subfield>
    <subfield code="d">29355</subfield>
  </datafield>
</record>
