<?xml version="1.0" encoding="UTF-8"?>
<mods xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" version="3.1" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
  <titleInfo>
    <title>Dynamic modelling of a biomass fuelled intermittent absorption ice making machine for remote rural areas</title>
  </titleInfo>
  <name type="personal">
    <namePart>Wynn, Kyaw</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Saunier, G.Y.</namePart>
    <role>
      <roleTerm type="text">Chairperson</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Reddy, T. A.</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Bhattacharya, Sribas C.</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <name type="corporate">
    <namePart>EEC (Commission of the European Communities)</namePart>
    <role>
      <roleTerm type="text">Scholarship Donor</roleTerm>
    </role>
  </name>
  <typeOfResource>text</typeOfResource>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">th</placeTerm>
    </place>
    <place>
      <placeTerm type="text">Bangkok</placeTerm>
    </place>
    <publisher>Asian Institute of Technology</publisher>
    <dateIssued>1984</dateIssued>
    <issuance>monographic</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <extent>80 p.</extent>
  </physicalDescription>
  <abstract>A detailed dynamic model of a biomass fueled aqua-ammonia intermittent absorption refrigerator is reported. Biomass fuel feeding rate is the required input. Generator temperature, Ice Box temperature, Ammonia distilled rate, ammonia vaporization rate and effect of mass inertia of the various components can be predicted. A computerized ideal mathematical model is also presented. The programs are written in FORTRAN IV computing language. State point temperatures, pressures, ammonia concentrations, enthalpies, mass and efficiency of the cycle can be predicted. All the units are expressed in SI Units. Effects of ambient temperature changes is also presented.  Experimental determination of relevant heat transfer data and Economic Evaluation are also included. Sensitivity analysis on the economic parameters is investigated. The Economic Evaluation showed that the Payback Period is about three years based on the city price of ice. Finally, several recommendations for future investigations are made.</abstract>
  <note>A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Environment, Resources &amp; Development</note>
  <note>Thesis (M.Eng.) - Asian Institute of Technology, 1984</note>
  <subject authority="lcsh">
    <topic>Refrigeration and refrigerating machinery</topic>
  </subject>
  <subject authority="lcsh">
    <topic>Biomass energy</topic>
  </subject>
  <relatedItem type="series">
    <titleInfo>
      <title>Thesis ; no. ET-84-2</title>
    </titleInfo>
    <name type="corporate">
      <namePart>Asian Institute of Technology.</namePart>
      <namePart/>
    </name>
  </relatedItem>
  <identifier type="uri">http://203.159.5.9/ait-thesis/detail.php?q=B20837</identifier>
  <location>
    <url displayLabel="Full-Text">http://203.159.5.9/ait-thesis/detail.php?q=B20837</url>
  </location>
  <recordInfo>
    <recordCreationDate encoding="marc">250998</recordCreationDate>
    <recordChangeDate encoding="iso8601">20260818094252.0</recordChangeDate>
  </recordInfo>
</mods>