<?xml version="1.0" encoding="UTF-8"?>
<mods xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" version="3.1" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
  <titleInfo>
    <title>Economics and safety of tall building design based on 2D frame analysis</title>
  </titleInfo>
  <name type="personal">
    <namePart>Leung, Chun-wai</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Worsak Kanok-Nukulchai</namePart>
    <role>
      <roleTerm type="text">Chairperson</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Pichai Nimityongskul</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Ueda, Tamon</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <name type="corporate">
    <namePart>The Government of Japan</namePart>
    <role>
      <roleTerm type="text">Scholarship Donor</roleTerm>
    </role>
  </name>
  <typeOfResource>text</typeOfResource>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">th</placeTerm>
    </place>
    <place>
      <placeTerm type="text">Bangkok</placeTerm>
    </place>
    <publisher>Asian Institute of Technology</publisher>
    <dateIssued>1990</dateIssued>
    <issuance>monographic</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <form authority="marcform">print</form>
    <extent>86 p.</extent>
  </physicalDescription>
  <abstract>Many three-dimensional multistory tall buildings are analyzed using simplified 2D frame  analytical techniques and plane frame computer programs in practice. The accuracy of these  design techniques may not be sufficient to ensure an economics and safety design because  important factors are neglected in the techniques. To evaluate the economics and safety of tall  building design based on 2D frame analysis, tall building models with varying building  parameters are tested by 2D frame analysis and more rigorous by 3D analysis. A real case study  of tall building in Thailand are tested also.  The results show that for frame building system without shearwall, a design based on  simplified 2D frame analysis under static or dynamic load is acceptable. Coupled frame-shearwall  building will be over-designed if results of 2D analysis are used especially at lower stories for  building which basically deform in bending mode and of which the number of stories is above  twenty five. Tall building designed from results of a three-dimensional analysis can very well  resist the worst loading condition as expected. Building design based on 2D frame analysis is  partly over-designed and partly unsafe</abstract>
  <note>A thesis submitted in partial fulfillments of the requirements for the degree of Master of Engineering, School of Engineering and Technology</note>
  <note>Thesis (M.Eng.) - Asian Institute of Technology, 1990</note>
  <subject authority="lcsh">
    <topic>Tall buildings</topic>
  </subject>
  <subject authority="lcsh">
    <topic>Structures, Theory of</topic>
  </subject>
  <relatedItem type="series">
    <titleInfo>
      <title>Thesis ; no. ST-90-10</title>
    </titleInfo>
    <name type="corporate">
      <namePart>Asian Institute of Technology.</namePart>
      <namePart/>
    </name>
  </relatedItem>
  <identifier type="uri">http://203.159.5.9/ait-thesis/detail.php?q=B18551</identifier>
  <location>
    <url displayLabel="Full-text">http://203.159.5.9/ait-thesis/detail.php?q=B18551</url>
  </location>
  <recordInfo>
    <recordCreationDate encoding="marc">270798</recordCreationDate>
    <recordChangeDate encoding="iso8601">20260818094711.0</recordChangeDate>
  </recordInfo>
</mods>