<?xml version="1.0" encoding="UTF-8"?>
<mods xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" version="3.1" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
  <titleInfo>
    <title>Effects of anaerobic conditions on biological phosphorus removal and sludge settleability</title>
  </titleInfo>
  <name type="personal">
    <namePart>Ouyang Ming</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Lee, Seong-Key</namePart>
    <role>
      <roleTerm type="text">Chairperson</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Samorn Muttamara</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Tanaka, Shuzo</namePart>
    <role>
      <roleTerm type="text">Examination committee</roleTerm>
    </role>
  </name>
  <name type="corporate">
    <namePart>Royal Government of Denmark</namePart>
    <role>
      <roleTerm type="text">Scholarship donor</roleTerm>
    </role>
  </name>
  <typeOfResource>text</typeOfResource>
  <genre authority="marc">series</genre>
  <genre authority="marc">technical report</genre>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">th</placeTerm>
    </place>
    <place>
      <placeTerm type="text">Bangkok</placeTerm>
    </place>
    <publisher>Asian Institute of Technology</publisher>
    <dateIssued>1993</dateIssued>
    <issuance>continuing</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <extent>88 leaves + 1 online resource</extent>
  </physicalDescription>
  <abstract>The effects of anaerobic conditions on biological phosphorus removal and sludge settleability in anaerobic aerobic activated sludge process have been studied by both continuous flow and batch experiments. In the continuous flow experiments, ten systems with different anaerobic configurations and various anaerobic retention time were operated. It has been observed that the growth of some filamentous organisms was suppressed under three-compartment anaerobic cascades as results of more soluble COD reduction and substrate gradient in anaerobic zone. The systems with anaerobic cascades also showed good phosphorus removal. It has been observed that anaerobic retention time should long enough to reduce soluble COD to penetrate aerobic zone. Longer anaerobic retention time such as 3 and 5 hours resulted in better phosphorus removal. In those systems without anaerobic cascade, severe filamentous bulking took place, even though the anaerobic retention time were similar to those of cascade systems. In the batch experiment, effects of anaerobic retention time on phosphorus removal was confirmed, suitable anaerobic retention time could achieve a better performance of phosphorus removal.</abstract>
  <note>A thesis submitted in partial fulfillment of the requirement for the degree of Master of Engineering</note>
  <note>Thesis (M.Eng.) - Asian Institute of Technology, 1993</note>
  <subject authority="lcsh">
    <topic>Sewage</topic>
    <topic>Purification</topic>
    <topic>Phosphate removal</topic>
  </subject>
  <relatedItem type="series">
    <titleInfo>
      <title>Thesis ; no. EV-93-20</title>
    </titleInfo>
    <name type="corporate">
      <namePart>Asian Institute of Technology.</namePart>
      <namePart/>
    </name>
  </relatedItem>
  <identifier type="uri">http://203.159.5.9/ait-thesis/detail.php?q=B16230</identifier>
  <location>
    <url displayLabel="Full-Text">http://203.159.5.9/ait-thesis/detail.php?q=B16230</url>
  </location>
  <recordInfo>
    <recordCreationDate encoding="marc">230399</recordCreationDate>
    <recordChangeDate encoding="iso8601">20260818095213.0</recordChangeDate>
  </recordInfo>
</mods>