<?xml version="1.0" encoding="UTF-8"?>
<mods xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" version="3.1" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
  <titleInfo>
    <title>Energy analysis of cogeneration in a palm oil factory</title>
  </titleInfo>
  <name type="personal">
    <namePart>Dechadule Thavornkit</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Prida Wibulswas</namePart>
    <role>
      <roleTerm type="text">Chairperson</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Bhattacharya, Sribas C.</namePart>
    <role>
      <roleTerm type="text">Co-Chairperson</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Lucas, N.J.D.</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <name type="corporate">
    <namePart>SHELL/UNESCO</namePart>
    <role>
      <roleTerm type="text">Scholarship Donor</roleTerm>
    </role>
  </name>
  <typeOfResource>text</typeOfResource>
  <genre authority="marc">series</genre>
  <genre authority="marc">technical report</genre>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">th</placeTerm>
    </place>
    <place>
      <placeTerm type="text">Bangkok</placeTerm>
    </place>
    <publisher>Asian Institute of Technology</publisher>
    <dateIssued>1987</dateIssued>
    <issuance>continuing</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <extent>144 p.</extent>
  </physicalDescription>
  <abstract>The palm oil industry, being a fairly new industry in  Thailand, has not been the subject of any previous energy study.  The study was limited to the normal operation of the cogeneration  and electrical system of a palm oil mill plant. An energy audit  was conducted and first and second law thermodynamic analysis  were made. The results show that the cogeneration system first  law efficiency is on average about 28.3% and the second law  efficiency is about 9.2%. The heat to power ratio of the system  is on average about 12 during off peak periods and 8.1 during on  peak periods. The analysjs showed that the low efficiency of the  system is due to the large difference between the steam  requirement to generate electricity and process steam needs  resulting in excessive steam blowout, as well as, low boiler and  turbine efficiencies.  The boiler first l aw efficiency is on average equal to 52.3%  and the turbine efficiency is 50.5%. The results pin-pointed high  moisture content in the fuel, high flue gas temperature and too  much excess air as the main cause of low boiler efficiency, and  steam throttling as the major cause of low turbine efficiency.  The heat to power ratio is quite low during on peak periods, i .e.  when the KO plant , which is a relatively new addition, is  likewise operating, emphasizing the fact that the plant has  evolved into a system requiring a large amount of electrical  energy compared to thermal energy.  Modeling equation for the boiler and turbogenerator were set  up . Simulation of the cogeneration system was also attempted The  modeling equations and simulation were found to agree fairly well  with available test data.  Energy conservation measures towards recovering some of the  excess steam and improvements in the electrical system to reduce  electrical load were analyzed. The results s how that a potential  total saving of 944,000 Baht/year which is 20% of total 1986  energy cost of the factory may be achieved. The proposed  implementable measures arc: utilization of excess steam to  preheat the pressurized boiler feedwater and nonutilization of  the generator capacitor when cogenerating electricity.</abstract>
  <note>A research study (9 credits) submitted in partial fulfillment of the requirement for the degree of Master of Engineering, School of Environment, Resources and Development</note>
  <note>Research Studies Project Report (M. Eng..) - Asian Institute of Technology, 1987</note>
  <subject authority="lcsh">
    <topic>Palm-oil industry</topic>
  </subject>
  <subject authority="lcsh">
    <topic>Cogeneration of electric power and heat</topic>
  </subject>
  <relatedItem type="series">
    <titleInfo>
      <title>no. ET-87-22</title>
    </titleInfo>
    <name type="corporate">
      <namePart>Asian Institute of Technology.</namePart>
      <namePart>Research studies project report ;</namePart>
      <namePart/>
    </name>
  </relatedItem>
  <identifier type="uri">http://203.159.5.9/ait-thesis/detail.php?q=B19008</identifier>
  <location>
    <url displayLabel="Full-Text">http://203.159.5.9/ait-thesis/detail.php?q=B19008</url>
  </location>
  <recordInfo>
    <recordCreationDate encoding="marc">271198</recordCreationDate>
    <recordChangeDate encoding="iso8601">20260818095741.0</recordChangeDate>
  </recordInfo>
</mods>