<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>03174nas|a2200397 i 4500</leader>
  <controlfield tag="005">20260818095741.0</controlfield>
  <controlfield tag="008">261198s1986    th  uzm rtt  00|  a1eng d</controlfield>
  <datafield tag="035" ind1=" " ind2=" ">
    <subfield code="a">.b1023973x</subfield>
  </datafield>
  <datafield tag="099" ind1=" " ind2="9">
    <subfield code="a">AIT RSPR no. ET-86-10</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Balakrishnan, Sadras Vasudev</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
    <subfield code="a">Energy analysis of cogeneration in a sugar mill</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a">Bangkok :</subfield>
    <subfield code="b">Asian Institute of Technology,</subfield>
    <subfield code="c">1986</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">93 p.</subfield>
  </datafield>
  <datafield tag="490" ind1="1" ind2=" ">
    <subfield code="a">Research studies project report ;</subfield>
    <subfield code="v">no. ET-86-10</subfield>
  </datafield>
  <datafield tag="500" ind1=" " ind2=" ">
    <subfield code="a">A research study (6 credits) submitted in partial fulfillment of the requirement for the degree of Master of Engineering, School of Environment, Resources and Development</subfield>
  </datafield>
  <datafield tag="502" ind1=" " ind2=" ">
    <subfield code="a">Research Studies Project Report (M. Eng.) - Asian Institute of Technology, 1986</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">The cogeneration system in Khon - kaen sugar mill ltd., located  in Khon - kaen province was studied and the energy and exergy  analysis of the components of the cogeneration system was carried  out . The cogeneration system consists of four boilers each of  80t /hr capacity , three 5Mw turbogenerators and five 1 5 00HP milling  turbines and one 2000HP unigator turbine. The best case  efficiency of the boiler was found to be 62. 74 % and the worst  case efficiency was found to be 60 . 25%. Using the component  analysis the analysis of the cogeneration system as a whole was  carried out. The energy analysis indicate that the maximum first  law efficiency of the cogeneration system recorded was 60. 3 9%  The cogeneration system was modeled base don the experimental  data collected and a computer program was written which takes  into account the capacity limitations of the components of the  system. Based on the first and second law analysis and on the  model developed energy conservation measures were suggested to  improve the efficiency of the cogeneration system. Major energy  conservation measures suggested were, reduction of excess air  supplied to the boilers, installation of bagasse drier (The source  o f drying of bagasse will be the flue gas) and operating the  turbo generators, milling turbines and unigator turbines at their  rated capacity .</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Energy conservation</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Cogeneration of electric power and heat</subfield>
  </datafield>
  <datafield tag="700" ind1="0" ind2=" ">
    <subfield code="a">Prida Wibulswas, </subfield>
    <subfield code="e">Chairperson</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Bhattacharya, Sribas C.,</subfield>
    <subfield code="e">Co-Chairperson</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Sauter-Servaes, Florian, </subfield>
    <subfield code="e">Examination Committee</subfield>
  </datafield>
  <datafield tag="710" ind1="2" ind2=" ">
    <subfield code="a">CEC, </subfield>
    <subfield code="e">Scholaship Donor</subfield>
  </datafield>
  <datafield tag="810" ind1="2" ind2=" ">
    <subfield code="a">Asian Institute of Technology.</subfield>
    <subfield code="t">Research studies project report ;</subfield>
    <subfield code="v">no. ET-86-10</subfield>
  </datafield>
  <datafield tag="856" ind1=" " ind2=" ">
    <subfield code="3">Full-Text</subfield>
    <subfield code="u">http://203.159.5.9/ait-thesis/detail.php?q=B19506</subfield>
  </datafield>
  <datafield tag="907" ind1=" " ind2=" ">
    <subfield code="a">.b1023973x</subfield>
    <subfield code="b">mnait</subfield>
    <subfield code="c">y</subfield>
  </datafield>
  <datafield tag="902" ind1=" " ind2=" ">
    <subfield code="a">240401</subfield>
  </datafield>
  <datafield tag="998" ind1=" " ind2=" ">
    <subfield code="b">2</subfield>
    <subfield code="c">951012</subfield>
    <subfield code="d">m</subfield>
    <subfield code="e">a  </subfield>
    <subfield code="f">y</subfield>
    <subfield code="g">0</subfield>
  </datafield>
  <datafield tag="945" ind1=" " ind2=" ">
    <subfield code="l">mnait</subfield>
  </datafield>
  <datafield tag="945" ind1=" " ind2=" ">
    <subfield code="l">mnarc</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="c">22</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="c">40</subfield>
  </datafield>
  <datafield tag="909" ind1=" " ind2=" ">
    <subfield code="a">Barcode : 30050120615025</subfield>
    <subfield code="b">CREATED : 2012-11-09</subfield>
    <subfield code="c">RECORD # : i12694782</subfield>
    <subfield code="d">LPATRON : 0</subfield>
    <subfield code="e">LCHKIN : -</subfield>
    <subfield code="f"># RENEWALS : 0</subfield>
    <subfield code="g"># OVERDUE : 0</subfield>
    <subfield code="h">IUSE3 : 0</subfield>
    <subfield code="i">TOT CHKOUT : 0</subfield>
    <subfield code="j">TOT RENEW : 0</subfield>
  </datafield>
  <datafield tag="909" ind1=" " ind2=" ">
    <subfield code="a">Barcode : 30050160016290</subfield>
    <subfield code="b">CREATED : 2016-03-31</subfield>
    <subfield code="c">RECORD # : i12916742</subfield>
    <subfield code="d">LPATRON : 0</subfield>
    <subfield code="e">LCHKIN : -</subfield>
    <subfield code="f"># RENEWALS : 0</subfield>
    <subfield code="g"># OVERDUE : 0</subfield>
    <subfield code="h">IUSE3 : 0</subfield>
    <subfield code="i">TOT CHKOUT : 0</subfield>
    <subfield code="j">TOT RENEW : 0</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">37081</subfield>
    <subfield code="d">37081</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="a">MAIN</subfield>
    <subfield code="b">MAIN</subfield>
    <subfield code="c">mnait</subfield>
    <subfield code="d">2026-08-18</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">AIT RSPR no. ET-86-10</subfield>
    <subfield code="p">30050120615025</subfield>
    <subfield code="r">2026-08-18 09:57:41</subfield>
    <subfield code="t">3</subfield>
    <subfield code="w">2026-08-18</subfield>
    <subfield code="y">22</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="a">MAIN</subfield>
    <subfield code="b">MAIN</subfield>
    <subfield code="c">mnarc</subfield>
    <subfield code="d">2026-08-18</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">AIT RSPR no. ET-86-10</subfield>
    <subfield code="p">30050160016290</subfield>
    <subfield code="r">2026-08-18 09:57:41</subfield>
    <subfield code="w">2026-08-18</subfield>
    <subfield code="y">40</subfield>
  </datafield>
</record>
