<?xml version="1.0" encoding="UTF-8"?>
<mods xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" version="3.1" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
  <titleInfo>
    <title>Energy conservation in a typical Thai hotel in Bangkok</title>
  </titleInfo>
  <name type="personal">
    <namePart>Somchai Wongwises</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Lucas, N.J.D.</namePart>
    <role>
      <roleTerm type="text">Chairperson</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Prida Wibulswas</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Bhattacharya, Sribas C.</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <name type="corporate">
    <namePart>Government of Japan</namePart>
    <role>
      <roleTerm type="text">Scholarsip Donor</roleTerm>
    </role>
  </name>
  <typeOfResource>text</typeOfResource>
  <genre authority="marc">series</genre>
  <genre authority="marc">technical report</genre>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">th</placeTerm>
    </place>
    <place>
      <placeTerm type="text">Bangkok</placeTerm>
    </place>
    <publisher>Asian Institute of Technology</publisher>
    <dateIssued>1984</dateIssued>
    <issuance>continuing</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <extent>75 p.</extent>
  </physicalDescription>
  <abstract>This research is an attempt to investigate the possibility of energy conservation especially for mechanical systems in the Sheraton Hotel. Breakdowns of energy consumption of various energy systems such as the air-conditioning system and steam system have been done. Energy auditing has been carried out, thermal performance of the air-conditioning system and boilers have been analyzed. Energy conservation opportunities in various energy system are analyzed and recommended. The economic analysis of such conservation opportunities is studied using the pay back period and rate of return. The possible savings from the recommended measures can be about 4,865,000 baht/year of about 44% of the total hotel energy consumption in 1983. </abstract>
  <note>A research study submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Environment, Resources and Development</note>
  <note>Research Studies Project Report (M. Eng.) - Asian Institute of Technology, 1984</note>
  <subject authority="lcsh">
    <topic>Hotels, taverns, etc</topic>
    <topic>Energy conservation</topic>
  </subject>
  <subject authority="lcsh">
    <topic>Energy conservation</topic>
    <topic>Thailand</topic>
    <topic>Bangkok</topic>
  </subject>
  <relatedItem type="series">
    <titleInfo>
      <title>Research studies project report ; no. ET-84-4</title>
    </titleInfo>
    <name type="corporate">
      <namePart>Asian Institute of Technology.</namePart>
      <namePart/>
    </name>
  </relatedItem>
  <identifier type="uri">http://203.159.5.9/ait-thesis/detail.php?q=B20678</identifier>
  <location>
    <url displayLabel="Full-Text">http://203.159.5.9/ait-thesis/detail.php?q=B20678</url>
  </location>
  <recordInfo>
    <recordCreationDate encoding="marc">150699</recordCreationDate>
    <recordChangeDate encoding="iso8601">20260818095800.0</recordChangeDate>
  </recordInfo>
</mods>