<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>03669nas|a2200397 i 4500</leader>
  <controlfield tag="005">20260817162059.0</controlfield>
  <controlfield tag="008">271198s1987    th  uzm rtt  00|  a1eng d</controlfield>
  <datafield tag="035" ind1=" " ind2=" ">
    <subfield code="a">.b10065581</subfield>
  </datafield>
  <datafield tag="099" ind1=" " ind2="9">
    <subfield code="a">AIT RSPR no. ET-87-24</subfield>
  </datafield>
  <datafield tag="100" ind1="0" ind2=" ">
    <subfield code="a">Suchitra Ngamkajornvivat</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
    <subfield code="a">Alcohol distillation :</subfield>
    <subfield code="b">feasibility study of some energy conservation techniques</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a">Bangkok :</subfield>
    <subfield code="b">Asian Institute of Technology,</subfield>
    <subfield code="c">1987</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">157 p.</subfield>
  </datafield>
  <datafield tag="490" ind1="1" ind2=" ">
    <subfield code="a">Research studies project report ;</subfield>
    <subfield code="v">no. ET-87-24</subfield>
  </datafield>
  <datafield tag="500" ind1=" " ind2=" ">
    <subfield code="a">A research study (9 credits) submitted in partial fulfillment of the requirement for the degree of Master of Engineering, School of Environment, Resources and Development</subfield>
  </datafield>
  <datafield tag="502" ind1=" " ind2=" ">
    <subfield code="a">Research Studies Project Report (M. Eng..) - Asian Institute of Technology, 1987</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">A study on energy used in TISTR alcohol pilot plant, a  production capacity of 1500 litres anhydrous alcohol per day was  conducted . The total energy consumption of the plant was 21202.87  MJ/day . It comprised of 97.5% fuel oil and 2 . 5% electricity , by  quantity or 88 . 5% and 11.5% of the total energy bill for fuel oil  and electricity respectively.  Significant amount of energy , 99% of total energy , is  distributed to the distillation process.  The energy and availability analyses are used to identified  locations, type and true magnitudes of waste energy, including  losses and irreversibility from the system. These illustrated  that the first law efficiency of boiler are 63 . 60% and 78.09% for  the worst and best case respectively. And the major losses are  losses due to dry flue gas and uncounted loss . The second law  efficiency of boiler is 16.34% for the worst case and 20 . 06% for  the best case. Energy conservation opportunities in the thermal  energy systems are identified , analyzed and recommended.  For the steam generation system , the installation of  economizer is recommended to reduce the flue gas temperature . The  possible saving is approximately 30468 Baht/year.  In distillation, economic return of the potential  conservation measures , by using heat pump , are analysed . Two heat  pump systems are recommended. One is the reboiler flashing  system, the possible saving is approximately 132987 Baht/year  with nine month payback period. The other is external working  fluid system. It provided a 75288 Baht/year of net saving and  2 . 2 year payback period .  The application of membrane technology, pervaporation, was  carried out to study the feasibility of replacing azeotropic  distillation by pervaporation process to reduce significant  amount of energy consumption in distillation process.</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Energy conservation</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Alcohol as fuel</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Mora, Jean-Claude, </subfield>
    <subfield code="e">Chairperson</subfield>
  </datafield>
  <datafield tag="700" ind1="0" ind2=" ">
    <subfield code="a">Prida Wibulswas, </subfield>
    <subfield code="e">Examination Committee</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Bhattacharya, Sribas C.,</subfield>
    <subfield code="e">Examination Committee</subfield>
  </datafield>
  <datafield tag="710" ind1="2" ind2=" ">
    <subfield code="a">EEC, </subfield>
    <subfield code="e">Scholarship Donor</subfield>
  </datafield>
  <datafield tag="810" ind1="2" ind2=" ">
    <subfield code="a">Asian Institute of Technology.</subfield>
    <subfield code="t">Research studies project report ;</subfield>
    <subfield code="v">no. ET-87-24</subfield>
  </datafield>
  <datafield tag="856" ind1=" " ind2=" ">
    <subfield code="3">Full-Text</subfield>
    <subfield code="u">http://203.159.5.9/ait-thesis/detail.php?q=B19010</subfield>
  </datafield>
  <datafield tag="907" ind1=" " ind2=" ">
    <subfield code="a">.b10065581</subfield>
    <subfield code="b">mnait</subfield>
    <subfield code="c">y</subfield>
  </datafield>
  <datafield tag="902" ind1=" " ind2=" ">
    <subfield code="a">240409</subfield>
  </datafield>
  <datafield tag="998" ind1=" " ind2=" ">
    <subfield code="b">2</subfield>
    <subfield code="c">951012</subfield>
    <subfield code="d">m</subfield>
    <subfield code="e">a  </subfield>
    <subfield code="f">y</subfield>
    <subfield code="g">0</subfield>
  </datafield>
  <datafield tag="945" ind1=" " ind2=" ">
    <subfield code="l">mnait</subfield>
  </datafield>
  <datafield tag="945" ind1=" " ind2=" ">
    <subfield code="l">mnarc</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="c">20</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="c">40</subfield>
  </datafield>
  <datafield tag="909" ind1=" " ind2=" ">
    <subfield code="a">Barcode : 30050003123329</subfield>
    <subfield code="b">CREATED : 1995-10-13</subfield>
    <subfield code="c">RECORD # : i1006249x</subfield>
    <subfield code="d">LPATRON : 1011549</subfield>
    <subfield code="e">LCHKIN : 2006-07-28</subfield>
    <subfield code="f"># RENEWALS : 0</subfield>
    <subfield code="g"># OVERDUE : 0</subfield>
    <subfield code="h">IUSE3 : 0</subfield>
    <subfield code="i">TOT CHKOUT : 1</subfield>
    <subfield code="j">TOT RENEW : 0</subfield>
  </datafield>
  <datafield tag="909" ind1=" " ind2=" ">
    <subfield code="a">Barcode : 30050160015961</subfield>
    <subfield code="b">CREATED : 2016-03-31</subfield>
    <subfield code="c">RECORD # : i12917072</subfield>
    <subfield code="d">LPATRON : 0</subfield>
    <subfield code="e">LCHKIN : -</subfield>
    <subfield code="f"># RENEWALS : 0</subfield>
    <subfield code="g"># OVERDUE : 0</subfield>
    <subfield code="h">IUSE3 : 0</subfield>
    <subfield code="i">TOT CHKOUT : 0</subfield>
    <subfield code="j">TOT RENEW : 0</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">3789</subfield>
    <subfield code="d">3789</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="a">MAIN</subfield>
    <subfield code="b">MAIN</subfield>
    <subfield code="c">mnait</subfield>
    <subfield code="d">2026-08-17</subfield>
    <subfield code="g">10.00</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">AIT RSPR no. ET-87-24</subfield>
    <subfield code="p">30050003123329</subfield>
    <subfield code="r">2026-08-17 16:20:59</subfield>
    <subfield code="t">2</subfield>
    <subfield code="w">2026-08-17</subfield>
    <subfield code="y">20</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="a">MAIN</subfield>
    <subfield code="b">MAIN</subfield>
    <subfield code="c">mnarc</subfield>
    <subfield code="d">2026-08-17</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">AIT RSPR no. ET-87-24</subfield>
    <subfield code="p">30050160015961</subfield>
    <subfield code="r">2026-08-17 16:20:59</subfield>
    <subfield code="w">2026-08-17</subfield>
    <subfield code="y">40</subfield>
  </datafield>
</record>
