<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>03386cam a2200361Ma 4500</leader>
  <controlfield tag="005">20260818132513.0</controlfield>
  <controlfield tag="008">070418s2007    vaua    ob    001 0 eng d</controlfield>
  <datafield tag="020" ind1=" " ind2=" ">
    <subfield code="a">9780784471876</subfield>
  </datafield>
  <datafield tag="020" ind1=" " ind2=" ">
    <subfield code="a">0784471878</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
    <subfield code="a">.b12241696</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
    <subfield code="a">Gravity sanitary sewer design and construction /</subfield>
    <subfield code="c">prepared by a joint task force of the Environmental and Water Resources Institute and the Pipeline Division Committee on Pipeline Planning of the American Society of Civil Engineers and the Collection Systems Subcommittee of the Technical Practice Committee of the Water Environment Federation ; edited by Paul Bizier.</subfield>
  </datafield>
  <datafield tag="250" ind1=" " ind2=" ">
    <subfield code="a">2nd ed.</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a">Reston, VA :</subfield>
    <subfield code="b">American Society of Civil Engineers :</subfield>
    <subfield code="b">Environmental &amp; Water Resources Institute ;</subfield>
    <subfield code="a">[Alexandria, VA] :</subfield>
    <subfield code="b">Water Environment Federation,</subfield>
    <subfield code="c">2007.</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">1 online resource (xiii, 422 pages) :</subfield>
    <subfield code="b">illustrations.</subfield>
  </datafield>
  <datafield tag="490" ind1="1" ind2=" ">
    <subfield code="a">ASCE manuals and reports on engineering practice ;</subfield>
    <subfield code="v">no. 60</subfield>
  </datafield>
  <datafield tag="490" ind1="1" ind2=" ">
    <subfield code="a">WEF manual of practice ;</subfield>
    <subfield code="v">no. FD-5</subfield>
  </datafield>
  <datafield tag="504" ind1=" " ind2=" ">
    <subfield code="a">Includes bibliographical references and index.</subfield>
  </datafield>
  <datafield tag="505" ind1="0" ind2=" ">
    <subfield code="a">Organization and administration of sanitary sewer projects -- Surveys and investigations -- Quantity of wastewater -- Corrosion processes and controls in municipal wastewater collection systems -- Hydraulics of sewers -- Design of sanitary sewer systems -- Appurtenances and special structures -- Materials for sewer construction -- Structural requirements -- Construction contract documents -- Construction methods -- Trenchless design and construction.</subfield>
  </datafield>
  <datafield tag="506" ind1=" " ind2=" ">
    <subfield code="a">Access restricted to Ryerson students, faculty and staff.</subfield>
    <subfield code="5">CaOTR</subfield>
  </datafield>
  <datafield tag="520" ind1="1" ind2=" ">
    <subfield code="a">"Prepared by a Joint Task Force of the American Society of Civil Engineers (ASCE) and the Water Environment Federation (WEF), Gravity Sanitary Sewer Design and Construction, Second Edition (ASCE Manuals and Reports on Engineering Practice No. 60/WEF Manual of Practice No. FD-5) provides theoretical and practical guidelines for the design and construction of gravity sanitary sewers." "Gravity Sanitary Sewer Design and Construction, Second Edition covers the administrative and organizational phases of sanitary sewer projects, as well as the parameters necessary to establish the design criteria, complete the design, and award a construction contract. The Manual offers an in-depth discussion of commonly used trenchless and conventional methods of sanitary sewer construction." "This manual is an indispensable resource for engineers in the field of sanitary sewer structural and hydraulic design."--Jacket.</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Sewerage</subfield>
    <subfield code="x">Design and construction.</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Sanitary engineering.</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Bizier, Paul.</subfield>
  </datafield>
  <datafield tag="710" ind1="2" ind2=" ">
    <subfield code="a">Joint Task Force of the Environmental and Water Resources Institute and the Pipeline Division Committee on Pipeline Planning of the American Society of Civil Engineers and the Collection Systems Subcommittee of the Technical Practice Committee of the Water Environment Federation.</subfield>
  </datafield>
  <datafield tag="710" ind1="2" ind2=" ">
    <subfield code="a">Environmental and Water Resources Institute (U.S.)</subfield>
  </datafield>
  <datafield tag="710" ind1="2" ind2=" ">
    <subfield code="a">American Society of Civil Engineers.</subfield>
  </datafield>
  <datafield tag="710" ind1="2" ind2=" ">
    <subfield code="a">Water Environment Federation.</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
    <subfield code="3">Download: Knovel</subfield>
    <subfield code="u">https://app.knovel.com/hotlink/toc/id:kpGSSDCE0D/gravity-sanitary-sewer/gravity-sanitary-sewer</subfield>
  </datafield>
  <datafield tag="907" ind1=" " ind2=" ">
    <subfield code="a">.b12241696</subfield>
    <subfield code="b">mngc </subfield>
    <subfield code="c">n</subfield>
  </datafield>
  <datafield tag="902" ind1=" " ind2=" ">
    <subfield code="a">251209</subfield>
  </datafield>
  <datafield tag="998" ind1=" " ind2=" ">
    <subfield code="b">0</subfield>
    <subfield code="c">190207</subfield>
    <subfield code="d">e</subfield>
    <subfield code="e">h  </subfield>
    <subfield code="f">n</subfield>
    <subfield code="g">0</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">51737</subfield>
    <subfield code="d">51737</subfield>
  </datafield>
</record>
