<?xml version="1.0" encoding="UTF-8"?>
<mods xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" version="3.1" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
  <titleInfo>
    <title>Groundwater pollution from on-site sanitation in Dhaka, Bangladesh</title>
  </titleInfo>
  <name type="personal">
    <namePart>Rahman, Ahmad Faridur</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Orth, Hermann M.</namePart>
    <role>
      <roleTerm type="text">Chairperson</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Chongrak Polprasert</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Vigneswaran, Saravanamuthu</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <name type="corporate">
    <namePart>Royal Netherlands Government</namePart>
    <role>
      <roleTerm type="text">Scholarship Donor</roleTerm>
    </role>
  </name>
  <typeOfResource>text</typeOfResource>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">th</placeTerm>
    </place>
    <place>
      <placeTerm type="text">Bangkok</placeTerm>
    </place>
    <publisher>Asian Institute of Technology</publisher>
    <dateIssued>1987</dateIssued>
    <issuance>monographic</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <extent>84 p.</extent>
  </physicalDescription>
  <abstract>This study looked into the risk of groundwater pollution from  on-site sanitation in Dhaka, Bangladesh. A sizable proportion of the  city population do not have access to adequate water supply. Groundwater  is the major source of potable water for domestic use. Safe excreta  disposal facilities are also very limited in the area.  This study also evaluated the extent of groundwater pollution  in relation ' to on-site sanitation systems in the project area.  Groundwater quality was monitored at selected points for specified time  at regular interval. Later the data were analyzed for identifying the  probable sources of the pollutants; and investigating the factors  controlling their movement in the soil-water system. In addition, the  present water supply, sanitation, and health status of the area has also  been reviewed.  The results from t he experiments indicated the presence of  pollutants of fecal origin, such as fecal coliform, bacteriophage, and  nitrate, in almost all the samples analyzed. The extensive use of  unsewered disposal system has been identified as the major source of  pollutants. The hydrogeologic condition was found to be unsuitable for  the traditional methods of on-site sanitation. Routine monitoring and  detailed study has to be carried out for having a c l ear view of the  potential of groundwater pollution by on-site sanitation facilities in  the study area.</abstract>
  <note>A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Environment, Resources and Development</note>
  <note>Thesis (M.Eng.) - Asian Institute of Technology, 1987</note>
  <subject authority="lcsh">
    <topic>Water, Underground</topic>
    <topic>Pollution</topic>
    <topic>Bangladesh</topic>
    <topic>Dhaka</topic>
  </subject>
  <relatedItem type="series">
    <titleInfo>
      <title>Thesis ; no. EV-87-10</title>
    </titleInfo>
    <name type="corporate">
      <namePart>Asian Institute of Technology.</namePart>
      <namePart/>
    </name>
  </relatedItem>
  <identifier type="uri">http://203.159.5.9/ait-thesis/detail.php?q=B19216</identifier>
  <location>
    <url displayLabel="Full-Text">http://203.159.5.9/ait-thesis/detail.php?q=B19216</url>
  </location>
  <recordInfo>
    <recordCreationDate encoding="marc">011298</recordCreationDate>
    <recordChangeDate encoding="iso8601">20260818132643.0</recordChangeDate>
  </recordInfo>
</mods>
