<?xml version="1.0" encoding="UTF-8"?>
<mods xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" version="3.1" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
  <titleInfo>
    <title>Heat of hydration of concrete containing Mae Moh fly ash</title>
  </titleInfo>
  <name type="personal">
    <namePart>Kang, Ing-ren</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Pichai Nimityongskul</namePart>
    <role>
      <roleTerm type="text">Chairperson</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Brotton, D.M.</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Karasudhi, Pisidhi</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <name type="corporate">
    <namePart>Government of R. 0. C., Scholarship Donor</namePart>
  </name>
  <typeOfResource>text</typeOfResource>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">th</placeTerm>
    </place>
    <place>
      <placeTerm type="text">Bangkok</placeTerm>
    </place>
    <publisher>Asian Institute of Technology</publisher>
    <dateIssued>1986</dateIssued>
    <issuance>monographic</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <form authority="marcform">print</form>
    <extent>80 p.</extent>
  </physicalDescription>
  <abstract>A feasibility study on the use of fly ash collected from the  Mae Moh Lignit e Power Plant as a pozzolana in mass concrete is  conducted.  Among the physical and mechanical properties investigated  are the chemical composition, water requirement, pozzolanic  activity index, initial and final setting times, compressive  strengths, and heat of hydration. The main parameter considered  in the experimental program is  the percentage of fly ash  replacement. All tests are conducted in accordance with ASTM standards except the test for heat of hydration which followed the British Standards Institution.   Test  results shows that the chemical composition and physical  properties of Ma e Moh fly as h satisfied the ASTM requirements and can be classified as pozzolana class C. This is  the first time that fly ash samples collected from the Mae Moh Lignite Power Plant met the specifications given by the American  Society for Testing and Materials Standards. At early ages,  the strength of fly ash cement mortars were lower than those of the corresponding control mortars, however , at later ages, up to  90 days, the strengths of fly ash cement mortars were  substantially higher than that of the corresponding control  mortar. It is recommended that fly ash can be used as  replacement for cement up to 35 percent without adverse effects  on the concrete. The combination of fly ash and Portland cement  produced a lower heat of hydration and a consequently lower  temperature rise than an equal amount of portland cement without  fly ash. The rate of heat evolution of fly ash was very much  slower than that of the ordinary portland cement during the early  age which is considered as the critical period in mass  concreting.</abstract>
  <note>A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Engineering and Technology</note>
  <note>Thesis (M.Eng.) - Asian Institute of Technology, 1986</note>
  <subject authority="lcsh">
    <topic>Heat of hydration</topic>
  </subject>
  <subject authority="lcsh">
    <topic>Fly ash</topic>
  </subject>
  <subject authority="lcsh">
    <topic>Concrete construction</topic>
  </subject>
  <relatedItem type="series">
    <titleInfo>
      <title>Thesis ; no. ST-86-12</title>
    </titleInfo>
    <name type="corporate">
      <namePart>Asian Institute of Technology.</namePart>
      <namePart/>
    </name>
  </relatedItem>
  <identifier type="uri">http://203.159.5.9/ait-thesis/detail.php?q=B19740</identifier>
  <location>
    <url displayLabel="Full-Text">http://203.159.5.9/ait-thesis/detail.php?q=B19740</url>
  </location>
  <recordInfo>
    <recordCreationDate encoding="marc">310798</recordCreationDate>
    <recordChangeDate encoding="iso8601">20260818133405.0</recordChangeDate>
  </recordInfo>
</mods>