<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>04190nas|a2200385 i 4500</leader>
  <controlfield tag="005">20260818133954.0</controlfield>
  <controlfield tag="008">070200s1999    th uu m rtt  00|  a1eng d</controlfield>
  <datafield tag="035" ind1=" " ind2=" ">
    <subfield code="a">.b11777370</subfield>
  </datafield>
  <datafield tag="099" ind1=" " ind2="9">
    <subfield code="a">AIT Thesis no.ET-99-8</subfield>
  </datafield>
  <datafield tag="100" ind1="0" ind2=" ">
    <subfield code="a">Khin Sandar Win</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="2">
    <subfield code="a">A hybrid approach to transient stability analysis</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a">Bangkok :</subfield>
    <subfield code="b">Asian Institute of Technology,</subfield>
    <subfield code="c">1999</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">126 leaves</subfield>
  </datafield>
  <datafield tag="490" ind1="1" ind2=" ">
    <subfield code="a">Thesis ;</subfield>
    <subfield code="v">no. ET-99-8</subfield>
  </datafield>
  <datafield tag="500" ind1=" " ind2=" ">
    <subfield code="a">A thesis submitted in partial fulfillment of the requirements for the degree of  Master of Engineering, School of Environment, Resources and Development </subfield>
  </datafield>
  <datafield tag="502" ind1=" " ind2=" ">
    <subfield code="a">Thesis (M.Eng.) - Asian Institute of Technology, 1999</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">Transient stability is the ability of a power system to maintain synchronism when  subjected to large and severe disturbance. An efficient algorithm is essential to assess the  transient stability in the modern power system. Several algorithms are developed for the  analysis of Transient Stability. A hybrid method developed by Y Zhang et.al [ZWRP 97}  assess the transient stability quite effectively since it couples both the time domain  program and the direct method. The strength of this method is namely: the modeling of  each machine and analysis of detail dynamic behavior during disturbance of Time  Domain Simulation and calculation of stability limit and margin of the whole system for  any condition using direct method.  This thesis presents an algorithm based on the hybrid (time domain- direct method)  for assessing the transient stability analysis combining the Time Domain as well as the  direct method. First, the system stability is checked based on the Time Domain Simulation  Algorithm. This algorithm uses the loadflow output obtained from the software package  developed by D. Thukaram, IISc Bangalore, India as the input data along with machine  details and system parameters and generates the reduced Y-bus for all conditions viz.  Prefault, During and Post fault conditions. Further swing equation is solved for each  machine using the Predictor Corrector method as a part of time domain analysis. The  result obtained from time Domain Simulation Algorithm is compared with the developed  algorithm by D. Thukaram, !!Sc Bangalore, and India.  This thesis also presents an algorithm from the Time Domain Simulation to assess  the transient stability of multimachine system via a Single Machine Infinite Bus system.  Here the stability margin and stability limit for SMIB is computed by the equal area  criterion. The stable margin is computed if the system is stable. Else, the unstable margin  is found out for the specified clearing time. Further, the clearing time is modified and the  system stability is checked again based on time domain simulation. This is done iteratively  modifying the clearing time till the system become stable. The stability limit (Critical  Clearing Time) is calculated by using the pair of relevant unstable as well as stable  margin to interpolate the stability level corresponding to zero stable margin. This gives  the complete assessment of the system during any disturbance. The algorithm is tested on  two sample systems as well as on one practical system. </subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Transients (Electricity)</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Dhadbanjan, Thukaram,</subfield>
    <subfield code="e">Chairperson</subfield>
  </datafield>
  <datafield tag="700" ind1="0" ind2=" ">
    <subfield code="a">Surapong Chiraratananon,</subfield>
    <subfield code="e">Examination Committee</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Yu, Cun Yi,</subfield>
    <subfield code="e">Examination Committee</subfield>
  </datafield>
  <datafield tag="710" ind1="2" ind2=" ">
    <subfield code="a">Asian Development Bank, </subfield>
    <subfield code="e">Scholarship donor</subfield>
  </datafield>
  <datafield tag="810" ind1="2" ind2=" ">
    <subfield code="a">Asian Institute of Technology.</subfield>
    <subfield code="t">Thesis ;</subfield>
    <subfield code="v">no. ET-99-8</subfield>
  </datafield>
  <datafield tag="856" ind1=" " ind2=" ">
    <subfield code="3">Full-Text</subfield>
    <subfield code="u">http://203.159.5.9/ait-thesis/detail.php?q=B12031</subfield>
  </datafield>
  <datafield tag="907" ind1=" " ind2=" ">
    <subfield code="a">.b11777370</subfield>
    <subfield code="b">mnait</subfield>
    <subfield code="c">u</subfield>
  </datafield>
  <datafield tag="902" ind1=" " ind2=" ">
    <subfield code="a">240421</subfield>
  </datafield>
  <datafield tag="998" ind1=" " ind2=" ">
    <subfield code="b">0</subfield>
    <subfield code="c">000207</subfield>
    <subfield code="d">m</subfield>
    <subfield code="e">a  </subfield>
    <subfield code="f">u</subfield>
    <subfield code="g">2</subfield>
  </datafield>
  <datafield tag="945" ind1=" " ind2=" ">
    <subfield code="l">mnait</subfield>
  </datafield>
  <datafield tag="945" ind1=" " ind2=" ">
    <subfield code="l">mnarc</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="c">14</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="c">40</subfield>
  </datafield>
  <datafield tag="909" ind1=" " ind2=" ">
    <subfield code="a">Barcode : 30050120749576</subfield>
    <subfield code="b">CREATED : 2014-03-02</subfield>
    <subfield code="c">RECORD # : i12754936</subfield>
    <subfield code="d">LPATRON : 0</subfield>
    <subfield code="e">LCHKIN : -</subfield>
    <subfield code="f"># RENEWALS : 0</subfield>
    <subfield code="g"># OVERDUE : 0</subfield>
    <subfield code="h">IUSE3 : 0</subfield>
    <subfield code="i">TOT CHKOUT : 0</subfield>
    <subfield code="j">TOT RENEW : 0</subfield>
  </datafield>
  <datafield tag="909" ind1=" " ind2=" ">
    <subfield code="a">Barcode : 30050120365597</subfield>
    <subfield code="b">CREATED : 2016-06-15</subfield>
    <subfield code="c">RECORD # : i13036907</subfield>
    <subfield code="d">LPATRON : 0</subfield>
    <subfield code="e">LCHKIN : -</subfield>
    <subfield code="f"># RENEWALS : 0</subfield>
    <subfield code="g"># OVERDUE : 0</subfield>
    <subfield code="h">IUSE3 : 0</subfield>
    <subfield code="i">TOT CHKOUT : 0</subfield>
    <subfield code="j">TOT RENEW : 0</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">56680</subfield>
    <subfield code="d">56680</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="a">MAIN</subfield>
    <subfield code="b">MAIN</subfield>
    <subfield code="c">mnait</subfield>
    <subfield code="d">2026-08-18</subfield>
    <subfield code="g">50.00</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">AIT Thesis no.ET-99-8</subfield>
    <subfield code="p">30050120749576</subfield>
    <subfield code="r">2026-08-18 13:39:54</subfield>
    <subfield code="t">3</subfield>
    <subfield code="w">2026-08-18</subfield>
    <subfield code="y">14</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="a">MAIN</subfield>
    <subfield code="b">MAIN</subfield>
    <subfield code="c">mnarc</subfield>
    <subfield code="d">2026-08-18</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">AIT Thesis no.ET-99-8</subfield>
    <subfield code="p">30050120365597</subfield>
    <subfield code="r">2026-08-18 13:39:54</subfield>
    <subfield code="w">2026-08-18</subfield>
    <subfield code="y">40</subfield>
  </datafield>
</record>
