<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>06691nam a2200445   4500</leader>
  <controlfield tag="005">20260818143535.0</controlfield>
  <controlfield tag="008">071198s1998    th      r     000|0 eng d</controlfield>
  <datafield tag="035" ind1=" " ind2=" ">
    <subfield code="a">.b11722812</subfield>
  </datafield>
  <datafield tag="099" ind1=" " ind2="9">
    <subfield code="a">AIT Diss. no. WM-97-02</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Gautam, Tirtha Raj</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="3">
    <subfield code="a">An integrated simulation-MCDM-GIS approach for groundwater management</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a">Bangkok :</subfield>
    <subfield code="b">Asian Institute of Technology,</subfield>
    <subfield code="c">1998</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">250 leaves</subfield>
  </datafield>
  <datafield tag="490" ind1="1" ind2=" ">
    <subfield code="a">Dissertation ;</subfield>
    <subfield code="v">no. WM-97-02</subfield>
  </datafield>
  <datafield tag="500" ind1=" " ind2=" ">
    <subfield code="a">A dissertation submitted in partial fulfillment of the requirement for the Degree of Doctor of  Engineering, School of Civil Engineering</subfield>
  </datafield>
  <datafield tag="502" ind1=" " ind2=" ">
    <subfield code="a">Thesis (Ph.D.) - Asian Institute of Technology, 1998</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">An integrated framework for the management and monitoring of a multiaquifer system, considering the  interrelated factors and their interaction with each other, has been developed. The framework is comprised of  simulation models, geostatistical analysis, multicriterion decision making (MCDM) techniques, and geographic  information systems (GIS). The simulation models were used for the assessment of the system behavior in  quantitative terms. Geostatistical analysis was made to address the uncertainty associated with the estimation  process. The methodology was applied to analyze the management problem of the Bangkok multiaquifer system.  On the basis of the hydrogeological characteristics of the basin, flow system was conceptualized for the  flow simulator, MODFLOW. Trial and error calibration approach was employed in this study. Calibration was  guided by several measures of calibration target obtained from the geostatistical analysis of the observation data.  The final calibration run was considered to be satisfactory based on the criteria that the discrepancy between the  observed and the simulated piezometric head values were within the allowable range of error obtained from  geostatistical analysis of the observed data. From the several steps involved in modeling, it was realized that trial  and error calibration of a groundwater model can be enhanced by introducing the calibration target and level of  calibration through the geostatistical analysis of observed data. Similar approach was employed to develop the  MT3D based transport model and an one-dimensional consolidation model. Calibration for these models was not  as rigorous as flow modeling as the available information for these models were not sufficient to do so. The  subsidence model was calibrated for ten representative locations for which detailed stratigraphic information and  reliable historical observation were available.  All the three calibrated models were used to evaluate the potential development plan and policies of the  groundwater management authority. Six development scenarios were proposed considering the domestic and the  industrial water demand, its rising pauem over the past and expansion of the surface water supply network.  Prediction of the associated impact of the groundwater development including drawdown, water quality  deterioration and subsidence was made for the scenarios using the simulation models. Predictive analysis shows  that if proper action is not taken, state of the Bangkok groundwater water system is expected to deteriorate at  an alarming rate. With the measures proposed, stabilization of water level drop and salt water movement can be  expected but subsidence is expected to continue though the rate decreases significantly.  The tradeoff between ever increasing demand for water withdrawal and adverse environmental cum  socio-economic factors involved in the groundwater management were dealt with by using  multicriterion/multiobjective decision making (MCDM) approach. GIS assisted MCDM analysis (spatial MCDM)  was found to be a powerful tool for the investigation of the spatial distribution of the environmental impact  considering the multiple aspects of it such as water level drop, quality degradation and subsidence simultaneously.  A methodology for the design of a monitoring network for a multiaquifer system was also developed  addressing the issues of economy, operational and administrative convenience and monitoring of multiple  variables for a multiaquifer system. The methodology incorporating optimization, geostatistical analysis and  multicriterion evaluation is composed of three steps: quantification of estimation error through kriging,  optimization of the network layout for a particular variable using simulated annealing method and the MCDM  evaluation of the alternatives developed by repeating the optimization process for each variable to be monitored.  From practical point of view and financial availability, an optimal expansion strategy for the Bangkok aquifer  system was determined using the proposed methodology. It was found that the present groundwater monitoring  network has to be expanded. For two conditions that have been investigated namely the optimal expansion of the  monitoring network maintaining the existing network, and fully optimal design without considering the existing  stations, the analysis provided almost equally good performance for a network composed of 130 monitoring  stations. Thus optimal expansion is preferred to the fully optimal design which discards many of the existing well  without significant improvement in the performance. </subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Multiple criteria decision making</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Geographic information systems</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Groundwater</subfield>
    <subfield code="x">Management</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Gupta, Ashim Das,</subfield>
    <subfield code="e">Chairperson</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Loof, Rainer,</subfield>
    <subfield code="e">Examination Committee</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Vachi Ramnarong, </subfield>
    <subfield code="e">Examination committee</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Tabucanon, Mario T.,</subfield>
    <subfield code="e">Examination Committee</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Sadananda, Ramakoti,</subfield>
    <subfield code="e">Examination Committee</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">McBean, Edward A., </subfield>
    <subfield code="e">Examination committee</subfield>
  </datafield>
  <datafield tag="710" ind1="2" ind2=" ">
    <subfield code="a">Deutsche Gesellschaft Fur Technische Zusammenarbeit (GTZ), Federal Republic of Germany, </subfield>
    <subfield code="e">Scholarship donor</subfield>
  </datafield>
  <datafield tag="810" ind1="2" ind2=" ">
    <subfield code="a">Asian Institute of Technology.</subfield>
    <subfield code="t">Dissertation ;</subfield>
    <subfield code="v">no. WM-97-02</subfield>
  </datafield>
  <datafield tag="856" ind1=" " ind2=" ">
    <subfield code="3">Full-Text</subfield>
    <subfield code="u">http://203.159.5.9/ait-thesis/detail.php?q=B12951</subfield>
  </datafield>
  <datafield tag="907" ind1=" " ind2=" ">
    <subfield code="a">.b11722812</subfield>
    <subfield code="b">mnait</subfield>
    <subfield code="c">y</subfield>
  </datafield>
  <datafield tag="902" ind1=" " ind2=" ">
    <subfield code="a">240514</subfield>
  </datafield>
  <datafield tag="998" ind1=" " ind2=" ">
    <subfield code="b">0</subfield>
    <subfield code="c">980901</subfield>
    <subfield code="d">m</subfield>
    <subfield code="e">a  </subfield>
    <subfield code="f">y</subfield>
    <subfield code="g">3</subfield>
  </datafield>
  <datafield tag="945" ind1=" " ind2=" ">
    <subfield code="l">mnait</subfield>
  </datafield>
  <datafield tag="945" ind1=" " ind2=" ">
    <subfield code="l">mnarc</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="c">22</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="c">40</subfield>
  </datafield>
  <datafield tag="909" ind1=" " ind2=" ">
    <subfield code="a">Barcode : 30050120555031</subfield>
    <subfield code="b">CREATED : 2012-08-24</subfield>
    <subfield code="c">RECORD # : i12690880</subfield>
    <subfield code="d">LPATRON : 1023515</subfield>
    <subfield code="e">LCHKIN : 2012-11-27</subfield>
    <subfield code="f"># RENEWALS : 0</subfield>
    <subfield code="g"># OVERDUE : 0</subfield>
    <subfield code="h">IUSE3 : 1</subfield>
    <subfield code="i">TOT CHKOUT : 1</subfield>
    <subfield code="j">TOT RENEW : 1</subfield>
  </datafield>
  <datafield tag="909" ind1=" " ind2=" ">
    <subfield code="a">Barcode : 30050120234306</subfield>
    <subfield code="b">CREATED : 2016-03-30</subfield>
    <subfield code="c">RECORD # : i12914095</subfield>
    <subfield code="d">LPATRON : 0</subfield>
    <subfield code="e">LCHKIN : -</subfield>
    <subfield code="f"># RENEWALS : 0</subfield>
    <subfield code="g"># OVERDUE : 0</subfield>
    <subfield code="h">IUSE3 : 0</subfield>
    <subfield code="i">TOT CHKOUT : 0</subfield>
    <subfield code="j">TOT RENEW : 0</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">61562</subfield>
    <subfield code="d">61562</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="a">MAIN</subfield>
    <subfield code="b">MAIN</subfield>
    <subfield code="c">mnait</subfield>
    <subfield code="d">2026-08-18</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">AIT Diss. no. WM-97-02</subfield>
    <subfield code="p">30050120555031</subfield>
    <subfield code="r">2026-08-18 14:35:35</subfield>
    <subfield code="t">3</subfield>
    <subfield code="w">2026-08-18</subfield>
    <subfield code="y">22</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="a">MAIN</subfield>
    <subfield code="b">MAIN</subfield>
    <subfield code="c">mnarc</subfield>
    <subfield code="d">2026-08-18</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">AIT Diss. no. WM-97-02</subfield>
    <subfield code="p">30050120234306</subfield>
    <subfield code="r">2026-08-18 14:35:35</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2026-08-18</subfield>
    <subfield code="y">40</subfield>
  </datafield>
</record>
