<?xml version="1.0" encoding="UTF-8"?>
<mods xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" version="3.1" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
  <titleInfo>
    <title>Application of the lumen method for daylighting calculation in Thailand</title>
  </titleInfo>
  <name type="personal">
    <namePart>Intouch Prakobvanichkul</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Surapong Chiraratananon</namePart>
    <role>
      <roleTerm type="text">Chairperson</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Karmazsin, Etienne</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Bhattacharya, Sribas C.</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <name type="corporate">
    <namePart>Electricity Generating Authority of Thailand</namePart>
    <role>
      <roleTerm type="text">Scholarship Donor</roleTerm>
    </role>
  </name>
  <typeOfResource>text</typeOfResource>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">th</placeTerm>
    </place>
    <place>
      <placeTerm type="text">Bangkok</placeTerm>
    </place>
    <publisher>Asian Institute of Technology</publisher>
    <dateIssued>1994</dateIssued>
    <issuance>monographic</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <extent>149 leaves +1 online resource</extent>
  </physicalDescription>
  <abstract>This experimental theoretical study deals with application of the lumen method for daylighting calculation in Thailand. The prediction of interior daylight illuminance are performed based on measured exterior illuminance for different shading conditions by lumen method of daylighting calculation. The light aperture is alternately oriented to east and south compass to investigate the effect of sky luminance distribution relating to light aperture orientations. Daylight availability for Bangkok has been developed based on partly cloudy sky condition. The lumen method for both daylighting and electtic lighting are applied for establishing the performance characteristics of the integrated lighting system based on derived daylight availability. The performance characteristics are analyzed for different electric control strategy. Estimation of daylighting utilization fraction for the entire year are implemented based on four typical day on extremely solar declination angle to optimize the suitable electric control strategy for the room. Correlation of horizontal solar radiation to horizontal illuminance are presented as an initial finding of empirical models for Bangkok site. These empirical models are particularly suitable for used in daylighting energy studies since they are based on existing solar radiation data currently available.</abstract>
  <note>A thesis submitted in partial fulfilment of the requirement for the degree of Master of Engineering</note>
  <note>Thesis (M.Eng.) - Asian Institute of Technology, 1994</note>
  <subject authority="lcsh">
    <topic>Daylighting</topic>
    <topic>Thailand</topic>
  </subject>
  <relatedItem type="series">
    <titleInfo>
      <title>Thesis ; no. ET-94-32</title>
    </titleInfo>
    <name type="corporate">
      <namePart>Asian Institute of Technology.</namePart>
      <namePart/>
    </name>
  </relatedItem>
  <identifier type="uri"> http://203.159.5.9/ait-thesis/detail.php?q=B16979</identifier>
  <location>
    <url displayLabel="Full-Text"> http://203.159.5.9/ait-thesis/detail.php?q=B16979</url>
  </location>
  <recordInfo>
    <recordCreationDate encoding="marc">300998</recordCreationDate>
    <recordChangeDate encoding="iso8601">20260817162957.0</recordChangeDate>
  </recordInfo>
</mods>
