<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>05050nas a2200433 a 4500</leader>
  <controlfield tag="005">20260817163006.0</controlfield>
  <controlfield tag="008">170901s2014    th uu m rtt   0   a eng d</controlfield>
  <datafield tag="035" ind1=" " ind2=" ">
    <subfield code="a">.b1219024x</subfield>
  </datafield>
  <datafield tag="099" ind1=" " ind2="9">
    <subfield code="a">AIT Thesis no.ET-14-27</subfield>
  </datafield>
  <datafield tag="100" ind1="0" ind2=" ">
    <subfield code="a">Thanongsak Kaewsaibuathong</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
    <subfield code="a">Application of Wattmon for system design and performance improvement of solar PV systems</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a">Pathum Thani, Thailand :</subfield>
    <subfield code="b">Asian Institute of Technology,</subfield>
    <subfield code="c">2014</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">90 leaves :</subfield>
    <subfield code="b">ill.  +</subfield>
    <subfield code="e">1 online resource</subfield>
  </datafield>
  <datafield tag="490" ind1="1" ind2=" ">
    <subfield code="a">Thesis ;</subfield>
    <subfield code="v">no. ET-14-27</subfield>
  </datafield>
  <datafield tag="500" ind1=" " ind2=" ">
    <subfield code="a">A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering in Energy</subfield>
  </datafield>
  <datafield tag="502" ind1=" " ind2=" ">
    <subfield code="a">Thesis (M.Eng.) - Asian Institute of Technology, 2014</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">This research examined the battery charging and discharging characteristic by grid and by solar PV system to understand the conditions for improving the performance of the battery by the user. A study was also conducted to show how an effective load management in solar home system powered by PV using a monitoring and control device (Wattmon) can help in improving the overall performance of the system. The improvements would be in terms of increased useful energy output, increased overall efficiency, etc. Experiments  were  conducted  to  study  the  patterns  of  battery  charging  by  solar  and  grid electricity. It was found that the charge efficiency by solar electricity is limited by the PV module efficiency, while the charging efficiency by grid electricity was around 80 %, though only 65 % of charging was observed during the bulk charge state and the remaining charging takes  a  long  time.  Therefore,  the  option  to  improve  charging  efficiency  in  case  of  a  PV system is by using the backup source only during the bulk charge state. Experimental studies on the patterns of battery discharging were conducted at c-rate of C/10, C/14, C/20 and C/30, respectively. It was found that discharge efficiency increases when discharge current is low. This  needs  effective  load  management  to  improve  the  performance.  In  addition,  the discharge time of battery can be calculated from different state of charge (SOC) conditions and discharge rate by Peukert{u2019}s equation and rate of SOC{u2019}s equation. This information can help to plan using the energy efficiently. The  demonstration  of  how  a  Solar  Home  System  (SHS)  will  continually  supply  essential load by load management according to SOC was also done. Essential load could be supplied when SOC ranges from 100 % to 30 %, and the non-essential loads could be supplied when SOC ranges from 100 % to 65 %. This way of energy supply to the load by the battery will improve  the performance  by  lower  discharge  current  rate.  This  load  management  by knowing  the  state  of  charge  and  the  types  and  needs  of  the  load  using  the  Wattmon monitoring  and  control  device  was  shown  to  be  effective.  However,  a  backup  source  is needed  in  stand-alone  solar  PV  system  in  order  to  guaranty  the  reliability  of  the  system during  continued  rainy  or  bad  weather  conditions. Another demonstration was  carried  out using excess energy to supply buffer load (the excess energy was produced by the PV system after having charged the battery fully). This will help improve the performance of solar PV system by using direct electricity from PV output to power the buffer load, and thus which can avoid losses, and increasing the useful energy supplied by the PV module. In summary, this research demonstrates how the overall efficiency and reliability of stand-alone  solar  PV  system  can  be  improved  by  using  a  monitoring  and  control  device  called 2Wattmon3.</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Storage batteries </subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Solar cells</subfield>
    <subfield code="x">Design and construction</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Photovoltaic power systems</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Kumar, Sivanappan,</subfield>
    <subfield code="e">Chairperson</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Singh, Jai Govind,</subfield>
    <subfield code="e">Examination Committee</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Mohanty, Brahmanand, </subfield>
    <subfield code="e">Examination Committee</subfield>
  </datafield>
  <datafield tag="710" ind1="2" ind2=" ">
    <subfield code="a">PEA,</subfield>
    <subfield code="e">Scholarship donor</subfield>
  </datafield>
  <datafield tag="710" ind1="2" ind2=" ">
    <subfield code="a">Asian Institute of Technology Education  Cooperation  Project,</subfield>
    <subfield code="e">Scholarship donor</subfield>
  </datafield>
  <datafield tag="710" ind1="2" ind2=" ">
    <subfield code="a">Asian Institute of Technology Fellowship, </subfield>
    <subfield code="e">Scholarship donor</subfield>
  </datafield>
  <datafield tag="810" ind1="2" ind2=" ">
    <subfield code="a">Asian Institute of Technology.</subfield>
    <subfield code="t">Thesis ;</subfield>
    <subfield code="v">no. ET-14-27</subfield>
  </datafield>
  <datafield tag="856" ind1=" " ind2=" ">
    <subfield code="3">Full-Text</subfield>
    <subfield code="u">http://203.159.5.9/ait-thesis/detail.php?q=B02323</subfield>
  </datafield>
  <datafield tag="907" ind1=" " ind2=" ">
    <subfield code="a">.b1219024x</subfield>
    <subfield code="b">mnait</subfield>
    <subfield code="c">m</subfield>
  </datafield>
  <datafield tag="902" ind1=" " ind2=" ">
    <subfield code="a">240418</subfield>
  </datafield>
  <datafield tag="998" ind1=" " ind2=" ">
    <subfield code="b">0</subfield>
    <subfield code="c">170901</subfield>
    <subfield code="d">m</subfield>
    <subfield code="e">a  </subfield>
    <subfield code="f">m</subfield>
    <subfield code="g">0</subfield>
  </datafield>
  <datafield tag="962" ind1=" " ind2=" ">
    <subfield code="a">000:001:PDF:b1219024:003359:0:0:0:0:0:0</subfield>
    <subfield code="t">Click to view Abstract</subfield>
    <subfield code="v">n</subfield>
  </datafield>
  <datafield tag="945" ind1=" " ind2=" ">
    <subfield code="l">mnait</subfield>
  </datafield>
  <datafield tag="945" ind1=" " ind2=" ">
    <subfield code="l">mnait</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="c">20</subfield>
  </datafield>
  <datafield tag="909" ind1=" " ind2=" ">
    <subfield code="a">Barcode : 30050120518559</subfield>
    <subfield code="b">CREATED : 2017-01-09</subfield>
    <subfield code="c">RECORD # : i13095225</subfield>
    <subfield code="d">LPATRON : 0</subfield>
    <subfield code="e">LCHKIN : -</subfield>
    <subfield code="f"># RENEWALS : 0</subfield>
    <subfield code="g"># OVERDUE : 0</subfield>
    <subfield code="h">IUSE3 : 0</subfield>
    <subfield code="i">TOT CHKOUT : 0</subfield>
    <subfield code="j">TOT RENEW : 0</subfield>
  </datafield>
  <datafield tag="909" ind1=" " ind2=" ">
    <subfield code="a">Barcode : 30050120518526</subfield>
    <subfield code="b">CREATED : 2017-01-09</subfield>
    <subfield code="c">RECORD # : i13095237</subfield>
    <subfield code="d">LPATRON : 0</subfield>
    <subfield code="e">LCHKIN : -</subfield>
    <subfield code="f"># RENEWALS : 0</subfield>
    <subfield code="g"># OVERDUE : 0</subfield>
    <subfield code="h">IUSE3 : 6</subfield>
    <subfield code="i">TOT CHKOUT : 0</subfield>
    <subfield code="j">TOT RENEW : 0</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">6942</subfield>
    <subfield code="d">6942</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="a">MAIN</subfield>
    <subfield code="b">MAIN</subfield>
    <subfield code="c">mnait</subfield>
    <subfield code="d">2026-08-17</subfield>
    <subfield code="g">50.00</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">AIT Thesis no.ET-14-27</subfield>
    <subfield code="p">30050120518559</subfield>
    <subfield code="r">2026-08-17 16:30:06</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2026-08-17</subfield>
    <subfield code="y">20</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="a">MAIN</subfield>
    <subfield code="b">MAIN</subfield>
    <subfield code="c">mnait</subfield>
    <subfield code="d">2026-08-17</subfield>
    <subfield code="g">50.00</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">AIT Thesis no.ET-14-27</subfield>
    <subfield code="p">30050120518526</subfield>
    <subfield code="r">2026-08-17 16:30:06</subfield>
    <subfield code="t">2</subfield>
    <subfield code="w">2026-08-17</subfield>
    <subfield code="y">20</subfield>
  </datafield>
</record>
