<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>04734nam a2200409   4500</leader>
  <controlfield tag="005">20260818155554.0</controlfield>
  <controlfield tag="008">270798         th                  eng  </controlfield>
  <datafield tag="035" ind1=" " ind2=" ">
    <subfield code="a">.b10449218</subfield>
  </datafield>
  <datafield tag="099" ind1=" " ind2="9">
    <subfield code="a">AIT Thesis no. ST-91-20</subfield>
  </datafield>
  <datafield tag="100" ind1="0" ind2=" ">
    <subfield code="a">Tanin Osotcharoenphol</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
    <subfield code="a">Modelling of heat generation process for cement in concrete</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a">Bangkok :</subfield>
    <subfield code="b">Asian Institute of Technology,</subfield>
    <subfield code="c">1991</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">46 p.</subfield>
  </datafield>
  <datafield tag="490" ind1="1" ind2=" ">
    <subfield code="a">Thesis ;</subfield>
    <subfield code="v">no. ST-91-20</subfield>
  </datafield>
  <datafield tag="500" ind1=" " ind2=" ">
    <subfield code="a">A thesis submitted in partial fulfillment of the requirements  for the degree of Master of Engineering, School of Engineering and Technology</subfield>
  </datafield>
  <datafield tag="502" ind1=" " ind2=" ">
    <subfield code="a">Thesis (M.Eng.) - Asian Institute of Technology, 1991</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">This research is aimed to set up a more generalized mathematical model for heat generation  process that is applicable to several types of cement. Cement particle is regarded as multi-component  material composed of four main compounds of cement i.e. ~A, C4AF, ~S and C2S. Each of these  chemical compounds is treated to have the same hydration characteristics as a single compound  when hydrate alone. C3A and C4AF are grouped according to their hydration rate as the most rapid  hydrating compound whereas C3S and C2S are regarded as the intermediate and the slowest hydrating  compounds respectively. Instead of using the conventional procedure, where the heat generation  rate is a function of time only, the coupled analysis of heat generation and heat conduction is  introduced. The heat generation rate is considered to depend upon the temperature and past hydration  process. The rate of heat generation process of cement compounds are calculated based upon the  Arrhenius's equation. The activation energy and maximum heat generation rate are assigned corresponding to the hydration characteristics of each compounds. The heat generation rate of cement  is computed from the summation of weighted heat of hydration generated by individual component  comprising cement.  An experimental program is performed to verify the analytical model. Thermocouples, which  are used as a temperature measuring device throughout the test program, are installed at various  positions of specimen before the placing of concrete. Thereafter, cubical concrete blocks insulated  all sides by foam plates with 2 inches in thickness except the top surface are casted with different  mix proportions and the temperature rise of concrete samples are measured at interval of 1 hour  upto 7 days.  The analytical results exhibit good corresponding with the experimental curves. It is noted  that the peak temperature obtained from the experiment and computational method occurred almost  at the same time, around 11 hours after placing of concrete. In the case of ordinary Portland cement,  the peak temperature is slightly lower than the predicted values. When cement partially replaced  with fly ash is introduced, the peak temperature become more of less the same. However, the  temperature rise predicted by the proposed model increase more slowly than the measured temperature while decreasing rate of temperature after the peak value become higher than the experimental results. The comparison between the temperature rise curve obtained from multi-component  model and temperature predicted by existing model is also carried out and satisfactory correlation  is attained. It can be realized that the multi component model introduces a new approach to deal  with prediction of temperature rise of any type cement possessing different chemical composition.</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Concrete</subfield>
    <subfield code="x">Chemistry</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Maekawa, Koichi, </subfield>
    <subfield code="e">Chairperson</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Karasudhi, Pisidhi, </subfield>
    <subfield code="e">Examination Committee</subfield>
  </datafield>
  <datafield tag="700" ind1="0" ind2=" ">
    <subfield code="a">Pichai Nimityongskul,</subfield>
    <subfield code="e">Examination Committee</subfield>
  </datafield>
  <datafield tag="710" ind1="2" ind2=" ">
    <subfield code="a">Government of New Zealand,</subfield>
    <subfield code="e">Scholarship Donor</subfield>
  </datafield>
  <datafield tag="810" ind1="2" ind2=" ">
    <subfield code="a">Asian Institute of Technology.</subfield>
    <subfield code="t">Thesis ;</subfield>
    <subfield code="v">no. ST-91-20</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
    <subfield code="3">Full-Text</subfield>
    <subfield code="u">http://203.159.5.9/ait-thesis/detail.php?q=B17728</subfield>
  </datafield>
  <datafield tag="907" ind1=" " ind2=" ">
    <subfield code="a">.b10449218</subfield>
    <subfield code="b">mnait</subfield>
    <subfield code="c">s</subfield>
  </datafield>
  <datafield tag="902" ind1=" " ind2=" ">
    <subfield code="a">250421</subfield>
  </datafield>
  <datafield tag="998" ind1=" " ind2=" ">
    <subfield code="b">2</subfield>
    <subfield code="c">951012</subfield>
    <subfield code="d">m</subfield>
    <subfield code="e">a  </subfield>
    <subfield code="f">s</subfield>
    <subfield code="g">0</subfield>
  </datafield>
  <datafield tag="945" ind1=" " ind2=" ">
    <subfield code="l">mnait</subfield>
  </datafield>
  <datafield tag="945" ind1=" " ind2=" ">
    <subfield code="l">mnait</subfield>
  </datafield>
  <datafield tag="945" ind1=" " ind2=" ">
    <subfield code="l">mnarc</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="c">20</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="c">40</subfield>
  </datafield>
  <datafield tag="909" ind1=" " ind2=" ">
    <subfield code="a">Barcode : 30050003065371</subfield>
    <subfield code="b">CREATED : 1995-10-15</subfield>
    <subfield code="c">RECORD # : i10562382</subfield>
    <subfield code="d">LPATRON : 0</subfield>
    <subfield code="e">LCHKIN : -</subfield>
    <subfield code="f"># RENEWALS : 0</subfield>
    <subfield code="g"># OVERDUE : 0</subfield>
    <subfield code="h">IUSE3 : 0</subfield>
    <subfield code="i">TOT CHKOUT : 0</subfield>
    <subfield code="j">TOT RENEW : 0</subfield>
  </datafield>
  <datafield tag="909" ind1=" " ind2=" ">
    <subfield code="a">Barcode : 30050003065363</subfield>
    <subfield code="b">CREATED : 1995-10-15</subfield>
    <subfield code="c">RECORD # : i10562394</subfield>
    <subfield code="d">LPATRON : 1011317</subfield>
    <subfield code="e">LCHKIN : 2003-11-28</subfield>
    <subfield code="f"># RENEWALS : 0</subfield>
    <subfield code="g"># OVERDUE : 0</subfield>
    <subfield code="h">IUSE3 : 0</subfield>
    <subfield code="i">TOT CHKOUT : 1</subfield>
    <subfield code="j">TOT RENEW : 0</subfield>
  </datafield>
  <datafield tag="909" ind1=" " ind2=" ">
    <subfield code="a">Barcode : 30050160022520</subfield>
    <subfield code="b">CREATED : 2016-04-04</subfield>
    <subfield code="c">RECORD # : i12922341</subfield>
    <subfield code="d">LPATRON : 0</subfield>
    <subfield code="e">LCHKIN : -</subfield>
    <subfield code="f"># RENEWALS : 0</subfield>
    <subfield code="g"># OVERDUE : 0</subfield>
    <subfield code="h">IUSE3 : 0</subfield>
    <subfield code="i">TOT CHKOUT : 0</subfield>
    <subfield code="j">TOT RENEW : 0</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">77734</subfield>
    <subfield code="d">77734</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="a">MAIN</subfield>
    <subfield code="b">MAIN</subfield>
    <subfield code="c">mnait</subfield>
    <subfield code="d">2026-08-18</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">AIT Thesis no. ST-91-20</subfield>
    <subfield code="p">30050003065371</subfield>
    <subfield code="r">2026-08-18 15:55:54</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2026-08-18</subfield>
    <subfield code="y">20</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="a">MAIN</subfield>
    <subfield code="b">MAIN</subfield>
    <subfield code="c">mnait</subfield>
    <subfield code="d">2026-08-18</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">AIT Thesis no. ST-91-20</subfield>
    <subfield code="p">30050003065363</subfield>
    <subfield code="r">2026-08-18 15:55:54</subfield>
    <subfield code="t">2</subfield>
    <subfield code="w">2026-08-18</subfield>
    <subfield code="y">20</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="a">MAIN</subfield>
    <subfield code="b">MAIN</subfield>
    <subfield code="c">mnarc</subfield>
    <subfield code="d">2026-08-18</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">AIT Thesis no. ST-91-20</subfield>
    <subfield code="p">30050160022520</subfield>
    <subfield code="r">2026-08-18 15:55:54</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2026-08-18</subfield>
    <subfield code="y">40</subfield>
  </datafield>
</record>
