<?xml version="1.0" encoding="UTF-8"?>
<mods xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" version="3.1" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
  <titleInfo>
    <title>A numerical study on the application of the sub-structure method for retrofitting</title>
    <subTitle>a case study of a school building in Dhaka, Bangladesh</subTitle>
  </titleInfo>
  <name type="personal">
    <namePart>May Chue Nyeint</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Krishna, Chaitanya</namePart>
    <role>
      <roleTerm type="text">Chairperson</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Pennung Warnitchai</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Anwar, Naveed</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <name type="corporate">
    <namePart>Loom Nam Khong Pijai (Greater Mekong Subregion) Scholarships</namePart>
    <role>
      <roleTerm type="text">Scholarship Donor</roleTerm>
    </role>
  </name>
  <typeOfResource>text</typeOfResource>
  <genre authority="marc">series</genre>
  <genre authority="marc">technical report</genre>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">th</placeTerm>
    </place>
    <place>
      <placeTerm type="text">Pathum Thani, Thailand</placeTerm>
    </place>
    <publisher>Asian Institute of Technology</publisher>
    <dateIssued>2024</dateIssued>
    <issuance>continuing</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <form authority="marcform">print</form>
    <extent>90 leaves : ill.+ 1 online resource</extent>
  </physicalDescription>
  <abstract>This thesis presents a numerical analysis aimed at assessing the effectiveness of  external sub-structure retrofitting methods for enhancing the seismic performance of a school building in Dhaka, Bangladesh. Due to the region{u2019}s geological conditions and  history of seismic events, improving the resilience of existing structures, particularly in densely populated and economically vital areas, is crucial. The study focuses on the  Kobbad Sardar Government Primary School, a two-story reinforced concrete (RC)  structure constructed under outdated seismic codes.The research employs the Applied Element Method (AEM) to evaluate three external  sub-structure retrofitting techniques: the Master Frame Construction Method, the Portal  Grid (PG) Method, and the External PT-PBSPC Frame Sub-Structure Method.  Numerical models of both the existing building and retrofitted configurations were  analyzed under static monotonic and incremental dynamic loads. Comparative  assessments were performed to evaluate seismic performance improvements in terms  of base shear capacity, drift ratio, ductility, crack pattern and deformation.Results from static analyses reveal significant enhancements in base shear capacity for  all retrofitted cases. While the un-retrofitted building achieves a base shear of 998 kN,  Retrofit-1 demonstrates the highest improvement at 2349 kN (a 135% increase),  followed by Retrofit-2 at 2157 kN and Retrofit-3 at 2311 kN. Incremental dynamic  analysis further confirms the effectiveness of retrofitting. For instance, under Imperial  Valley ground motions, the un-retrofitted structure suffers extensive damage, while all  retrofitted cases reduce this to slight damage with minimized deformation across all  PGA levels. Similarly, under Parkfield and Tottori ground motions, retrofitting  mitigates damage significantly, with Retrofit-3 exhibiting the best performance.Additionally, retrofitting slightly reduces the natural frequency of the structure,  signifying increased stiffness and improved resistance to seismic forces. These findings  highlight the importance of adopting external sub-structure retrofitting techniques for  similar buildings in Dhaka, ensuring enhanced safety, cost-effectiveness, and minimal  disruption. The proposed methods contribute to sustainable and resilient urban  infrastructure development in earthquake-prone regions.</abstract>
  <note>A thesis submitted in partial fulfillment of the requirements for the  degree of Master of Engineering in Structural Engineering</note>
  <note>Thesis (M. Eng.) - Asian Institute of Technology, 2024</note>
  <subject authority="lcsh">
    <topic>School buildings</topic>
    <topic>Retrofitting</topic>
    <geographic>Bangladesh</geographic>
  </subject>
  <subject authority="lcsh">
    <topic>School buildings</topic>
    <topic>Earthquake effects</topic>
    <geographic>Bangladesh</geographic>
  </subject>
  <subject authority="lcsh">
    <topic>Building repair</topic>
    <geographic>Bangkadesh</geographic>
  </subject>
  <relatedItem type="series">
    <titleInfo>
      <title>Thesis ; no. ST-24-27</title>
    </titleInfo>
    <name type="corporate">
      <namePart>Asian Institute of Technology.</namePart>
      <namePart/>
    </name>
  </relatedItem>
  <identifier type="uri">http://203.159.5.9/ait-thesis/Viewer/viewer.php?id=B23546</identifier>
  <location>
    <url displayLabel="Full-Text">http://203.159.5.9/ait-thesis/Viewer/viewer.php?id=B23546</url>
  </location>
  <recordInfo>
    <recordCreationDate encoding="marc">260202</recordCreationDate>
    <recordChangeDate encoding="iso8601">20260817161323.0</recordChangeDate>
  </recordInfo>
</mods>