<?xml version="1.0" encoding="UTF-8"?>
<mods xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" version="3.1" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
  <titleInfo>
    <title>Performance analysis of thermmal power generation</title>
    <subTitle>case of India</subTitle>
  </titleInfo>
  <name type="personal">
    <namePart>Bhattacharya, Sribas C.</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Shrestha, Ram M.</namePart>
    <role>
      <roleTerm type="text">Chairperson</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Bhattacharya, Sribas C.</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Edelman, David J.</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Zhai, Y.</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <name type="corporate">
    <namePart>The Government. of Netherlands</namePart>
    <role>
      <roleTerm type="text">Scholarship Donor</roleTerm>
    </role>
  </name>
  <typeOfResource>text</typeOfResource>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">th</placeTerm>
    </place>
    <place>
      <placeTerm type="text">Bangkok</placeTerm>
    </place>
    <publisher>Asian Institute of Technology</publisher>
    <dateIssued>1991</dateIssued>
    <issuance>monographic</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <extent>192 p.</extent>
  </physicalDescription>
  <abstract>In this study, performance of coal-fired thermal power generation in India is  analyzed at unit, plant and utility levels. At plant and utility levels, best practice  frontier analysis, a method to find relative efficiencies of units, is used. At unit  level and fo1· financial performance of unities, radio analysis is used where certain  ratios are considered at different levels. Ratio analysis is simple and yields  understandable results. Here it is used as relevant data required for other types  of analyses were not available. Utilities are compared with selected Asian utilities  also. Policy aspects of performance studies are also included. Utilities are compared  from emission point of view. Overall emission from thermal power generation in the  past and its projection for the future are also presented.  It is found that a few plants are performing efficiently and majority of the  inefficient. plants employ more of labour, auxiliary power and capacity per output.  Plants of sizes up to 550 MW are found to perform better compared to bigger size  plants. Majority of the plants had fluctuating performance over time . Performance  of plants in Southern region was the best in the country and that of Eastern region  was the poorest. Plants owned and operated by private companies are performing  better than publicly owned ones.  Poor national averages of PLF and availability were due to: i) poor performance  of 110-120 MW units, ii) indigenous supply of equipment. which had high forced  outage rates that had arisen out of poor quality of coal and failure of turbine generators, main transformers etc. Regional variation in capacity utilization was  prominent - south being the best performer and eastern and north- eastern regions  being the poor performers. Availability of older units (above fifteen years of age)  were bette1· than the newer units.  Performance of bigger size utilities (6 GWH or more) are poorer than the smaller  size utilities and utilities with more hydro share are performing better. Best practice  Indian utilities are performing as good as some other Asian utilities in terms of  technical efficiency. Private utilities are performing better as compared to public  ones.</abstract>
  <note>A thesis submitted in partial fulfillment of the requirements for the  degree of Master of Engineering, School of Environment, Resources and Development</note>
  <note>Thesis (M.Eng.) - Asian Institute of Technology, 1991</note>
  <subject authority="lcsh">
    <topic>Thermal power plant</topic>
    <geographic>India</geographic>
  </subject>
  <relatedItem type="series">
    <titleInfo>
      <title>Thesis ; no. ET-91-15</title>
    </titleInfo>
    <name type="corporate">
      <namePart>Asian Institute of Technology.</namePart>
      <namePart/>
    </name>
  </relatedItem>
  <identifier type="uri">http://203.159.5.9/ait-thesis/detail.php?q=B17511</identifier>
  <location>
    <url displayLabel="Full-Text">http://203.159.5.9/ait-thesis/detail.php?q=B17511</url>
  </location>
  <recordInfo>
    <recordCreationDate encoding="marc">290998</recordCreationDate>
    <recordChangeDate encoding="iso8601">20260818171503.0</recordChangeDate>
  </recordInfo>
</mods>