    <title>Assessment of cogeneration potential of Thailand's sugar mills</title>
  </titleInfo>
  <name type="personal">
    <namePart>Apichit Therdyothin</namePart>
    <role>
      <roleTerm authority="marcrelator" type="text">creator</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Bhattacharya, Sribas C.</namePart>
    <role>
      <roleTerm type="text">Chairperson</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Surapong Chirarattananon</namePart>
    <role>
      <roleTerm type="text">Co-Chairperson</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Tabucanon, Mario T.</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Prida Wibulswas</namePart>
    <role>
      <roleTerm type="text">Examintion Committee</roleTerm>
    </role>
  </name>
  <name type="personal">
    <namePart>Williamson, A. G.</namePart>
    <role>
      <roleTerm type="text">Examination Committee</roleTerm>
    </role>
  </name>
  <name type="corporate">
    <namePart>Government of Japan</namePart>
    <role>
      <roleTerm type="text">Scholarship Donor</roleTerm>
    </role>
  </name>
  <typeOfResource>text</typeOfResource>
  <genre authority="marc">series</genre>
  <genre authority="marc">technical report</genre>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">th</placeTerm>
    </place>
    <place>
      <placeTerm type="text">Bangkok</placeTerm>
    </place>
    <publisher>Asian Institute of Technology</publisher>
    <dateIssued>1992</dateIssued>
    <issuance>continuing</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">eng</languageTerm>
  </language>
  <physicalDescription>
    <extent>97, [43] leaves</extent>
  </physicalDescription>
  <abstract>The cogeneration potential of sugar mills in Thailand has been studied. Models of the  , existing sugar mills developed show that the excess bagasse ·is 12 % of produced bagasse or 1.02  million tons which can generate approximately 214 GWh of electricity. To achieve more excess  bagasse, four energy conservation opportunities, e.g. boiler excess air control, bagasse dryer,  condensation heat recovery of flue gas and use of thermo-compressor in multiple effect evaporator  have been studied. The results show that the total excess bagasse potential is about 28 % of produced  bagasse.  Four alternatives have been considered to increase the electricity generation potential from  excess bagasse. These are use of bagasse dryer, use of cane tops and leaves, use of high pressure  boiler with single extraction-condensing steam turbine (SECST) and use of high pressure boiler with  double extraction-condensing steam turbine (DECST). The estimated costs of electricity generated  from these four alternatives are 1.23, 2.80, 7.28 and 7.08 C/kWh respectively.  To select the most suitable alternative that gives the maximum benefit to the country not, only  financial factor is considered but also the impacts on environment and the society. The analytic  hierarchy process (AHP) has been used to select the best alternative based on following criteria i)  Government investment, ii) Private investment, iii) Total operating cost, iv) S02 emission, v)  Employment generation, vi) Availability of local equipment, and vii) Dependency on foreign  assistance. The result of five decision makers from five related organization in Thailand show that  SECST and DECST system are the best alternatives due to their very low government investment and  S02 emission.  For maximum financial benefit to the sugar mills which apply SECST and DECST systems,  the proper size of boilers and turbo generators must be selected from the commercially available  equipments. Using mixed integer linear programming technique, the optimum size of the boilers and  turbo generators have been selected for small, large and very large sager mills. The annual benefit  of small, large and very large size sugar mills, if proper SECST system is used, is 1.3, 2.4 and 4.6  million US$ respectively while the benefit is 1.9, 4.4 and 6.4 million US$ respectively if DECST  system is used. </abstract>
  <note>A dissertation submitted in partial fulfillment of the requirements for the Degree of Doctor of Engineering, school of Environment, Resources &amp; Development</note>
  <note>Thesis (Ph.D.) - Asian Institute of Technology</note>
  <subject authority="lcsh">
    <topic>Cogeneration of electric power and heat</topic>
    <topic>Thailand</topic>
  </subject>
  <relatedItem type="series">
    <titleInfo>
      <title>Dissertation ; no. ET-92-01</title>
    </titleInfo>
    <name type="corporate">
      <namePart>Asian Institute of Technology.</namePart>
      <namePart/>
    </name>
  </relatedItem>
  <identifier type="uri">http://203.159.5.9/ait-thesis/detail.php?q=B16465</identifier>
  <location>
    <url displayLabel="Full-Text">http://203.159.5.9/ait-thesis/detail.php?q=B16465</url>
  </location>
  <recordInfo>
    <recordCreationDate encoding="marc">170699</recordCreationDate>
    <recordChangeDate encoding="iso8601">20260817163528.0</recordChangeDate>
  </recordInfo>
</mods>