<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>04122nas a2200385 a 4500</leader>
  <controlfield tag="005">20260818174745.0</controlfield>
  <controlfield tag="008">260202s20249999th u  ms t    000   eng d</controlfield>
  <datafield tag="035" ind1=" " ind2=" ">
    <subfield code="a">.b1247387x</subfield>
  </datafield>
  <datafield tag="099" ind1=" " ind2="9">
    <subfield code="a">AIT Thesis no.ST-24-26</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Jayasinghe, Rajasinghege Mahendra Deshapriya</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
    <subfield code="a">Progressive collapse analysis of steel transmission towers subjected to earthquakes with pulse effect using applied element method</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a">Pathum Thani, Thailand :</subfield>
    <subfield code="b">Asian Institute of Technology,</subfield>
    <subfield code="c">2024</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">77 leaves :</subfield>
    <subfield code="b">ill.+</subfield>
    <subfield code="e">1 online resource</subfield>
  </datafield>
  <datafield tag="490" ind1="1" ind2=" ">
    <subfield code="a">Thesis ;</subfield>
    <subfield code="v">no. ST-24-26</subfield>
  </datafield>
  <datafield tag="500" ind1=" " ind2=" ">
    <subfield code="a">A thesis submitted in partial fulfillment of the requirements for the  degree of Master of Engineering in Structural Engineering</subfield>
  </datafield>
  <datafield tag="502" ind1=" " ind2=" ">
    <subfield code="a">Thesis (M. Eng.) - Asian Institute of Technology, 2024</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">Steel electric transmission towers are crucial for supporting overhead powerlines and  are classified as lifeline structures. The most commonly used type of steel electric  transmission towers are suspension towers. These steel structures are generally  considered safe during seismic events. However, collapses have been observed under a  specific ground motion effect known as a pulse. Progressive collapse of transmission  towers can occur by sudden natural hazards like earthquakes, particularly when  influenced by pulse effects. This causes localized damage to structural elements, such  as load-bearing members, and leads to the failure of the entire structure or a significant  portion of it. Pulse effects are especially critical, being characterized by their short  duration, large amplitude, and rapid release of seismic energy. These intense forces can  cause transmission towers to fail, impacting the whole lifeline and may lead to a total  blackout.This research aims to examine the progressive collapse behavior of steel electric  transmission towers under pulse and non-pulse conditions of identical ground motions.  The Applied Element Method (ELS software) is used for numerical analysis on both wire-loaded and non-wire-loaded configurations of suspension-type towers subjected  to three ground motions.To extract pulse from the three ground motions, continuous  wavelet transform analysis is employed. Only the significant pulse was extracted.The results indicate that both wire-loaded and non-wire-loaded towers under pulse  conditions collapsed during the pulse duration. However, without pulse conditions both  towers only experienced minor damage without collapse. Non-wire-loaded tower  required peak ground acceleration (PGA) with pulse to collapse compared to wire loaded tower. Most of the higher displacements and elements failed at tower height  between 37.05 m to 42.55 m. It{u2019}s also identified as the critical location of both tower  configurations under pulse effects, with failure primarily due to the buckling effect.  When wire-loaded and non-wire-loaded towers collapse under pulse conditions, the  total energy-time graphs observe a significant release of energy (sudden sharp peak  during the collapse), while under non-pulse conditions for both towers, the energy curves remain constant towards the end. </subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Electric lines</subfield>
    <subfield code="x">Poles and towers</subfield>
    <subfield code="x">Earthquake effects</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Steel, Structural</subfield>
    <subfield code="x">Earthquake effects</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Finite element method</subfield>
    <subfield code="x">Data processing</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Krishna, Chaitanya,</subfield>
    <subfield code="e">Chairperson</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Anwar, Naveed,</subfield>
    <subfield code="e">Examination Committee</subfield>
  </datafield>
  <datafield tag="700" ind1="0" ind2=" ">
    <subfield code="a">Thanakorn Pheeraphan,</subfield>
    <subfield code="e">Examination Committee</subfield>
  </datafield>
  <datafield tag="710" ind1="2" ind2=" ">
    <subfield code="a">Computer and Structures Inc.(CSI), USA,</subfield>
    <subfield code="e">Scholarship Donor</subfield>
  </datafield>
  <datafield tag="710" ind1="2" ind2=" ">
    <subfield code="a">AIT Scholarship,</subfield>
    <subfield code="e">Scholarship Donor</subfield>
  </datafield>
  <datafield tag="810" ind1="2" ind2=" ">
    <subfield code="a">Asian Institute of Technology.</subfield>
    <subfield code="t">Thesis ;</subfield>
    <subfield code="v">no. ST-24-26</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
    <subfield code="3">Full-Text</subfield>
    <subfield code="u">http://203.159.5.9/ait-thesis/Viewer/viewer.php?id=B23545</subfield>
  </datafield>
  <datafield tag="907" ind1=" " ind2=" ">
    <subfield code="a">.b1247387x</subfield>
    <subfield code="b">mnarc</subfield>
    <subfield code="c">a</subfield>
  </datafield>
  <datafield tag="902" ind1=" " ind2=" ">
    <subfield code="a">260216</subfield>
  </datafield>
  <datafield tag="998" ind1=" " ind2=" ">
    <subfield code="b">0</subfield>
    <subfield code="c">260213</subfield>
    <subfield code="d">m</subfield>
    <subfield code="e">h  </subfield>
    <subfield code="f">a</subfield>
    <subfield code="g">0</subfield>
  </datafield>
  <datafield tag="945" ind1=" " ind2=" ">
    <subfield code="l">mnarc</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="c">67</subfield>
  </datafield>
  <datafield tag="909" ind1=" " ind2=" ">
    <subfield code="a">Barcode : -</subfield>
    <subfield code="b">CREATED : 2026-02-02</subfield>
    <subfield code="c">RECORD # : i1357050x</subfield>
    <subfield code="d">LPATRON : 0</subfield>
    <subfield code="e">LCHKIN : -</subfield>
    <subfield code="f"># RENEWALS : 0</subfield>
    <subfield code="g"># OVERDUE : 0</subfield>
    <subfield code="h">IUSE3 : 0</subfield>
    <subfield code="i">TOT CHKOUT : 0</subfield>
    <subfield code="j">TOT RENEW : 0</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">94641</subfield>
    <subfield code="d">94641</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="a">MAIN</subfield>
    <subfield code="b">MAIN</subfield>
    <subfield code="c">mnarc</subfield>
    <subfield code="d">2026-08-18</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">AIT Thesis no.ST-24-26</subfield>
    <subfield code="r">2026-08-18 17:47:45</subfield>
    <subfield code="t">1</subfield>
    <subfield code="w">2026-08-18</subfield>
    <subfield code="y">67</subfield>
  </datafield>
</record>
