245 1 0 _aStrengthening of reinforced concrete beam and slab system using ferrocement jacketing
260 _aPathum Thani, Thailand :
_bAsian Institute of Technology,
_c2004
300 _a68 leaves
490 1 _aThesis ;
_vno. ST-04-06
500 _aA thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Engineering and Technology
502 _aThesis (M.Eng.) - Asian Institute of Technology, 2004
520 _aThe structural behavior of reinforced concrete beam and slab system using Ferrocement jacketing are investigated. Ten specimens which included two control specimens, two specimens without ferrocement jacketing and six strengthened specimens are cast and tested for their structural performance. This study proposed three patterns of applying ferrocement jacketing on the beam and slab systems namely the single form layer, modified single form layer and double form layers. The first crack loads, ultimate loads, toughness and ductility of the composites are experimentally obtained and compared with the behavior of beam and slab systems without ferrocement jacketing. The experimental results are compared with predicted values and a cost analysis is conducted. Test results showed that strengthening of the beam and slab systems by using ferrocement jacketing increased the first crack and ultimate loads, modulus of resilience, and toughness index of the composite system. The double form layer ferrocement jacketing system resulted in a significant increase in the load carrying capacity of the composite. The experimental results with regard to the first crack and ultimate loads of the composite system were found to be significantly higher than the theoretical predicted values. The cost of the strengthening of the beam and slab systems using the single form layer, modified single form layer, and double form layers of ferrocement jacketing were 134, 210 and 151 Bath per ton of ultimate load respectively. It is recommended that the strengthening the beam and slab system using double form layers of ferrocement jacketing be adopted in practice due to the superior behavior of the composite.
650 0 _aReinforced concretes
650 0 _aConcrete beams
650 0 _aConcrete slabs
700 0 _aPichai Nimityongskul,
_eChairperson
700 1 _aTatsa, Elisha Zeev,
_eExamination committee
700 1 _aBarry, William Joseph,
_eExamination Committee
710 2 _aMahanakorn University of Technology, Thailand,
_eScholarship donor
810 2 _aAsian Institute of Technology.
_tThesis ;
_vno. ST-04-06
856 _3Full-Text
_u http://203.159.5.9/ait-thesis/detail.php?q=B08985
907 _a.b11938997
_bmnait
_cu
902 _a240422
998 _b0
_c040903
_dm
_ea
_fu
_g0
945 _lmnait
945 _lmnarc
942 _c22
942 _c40
909 _aBarcode : 30050120818801
_bCREATED : 2014-04-30
_cRECORD # : i12795021
_dLPATRON : 1025404
_eLCHKIN : 2015-05-10
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 1
_jTOT RENEW : 7
909 _aBarcode : 30050160068507
_bCREATED : 2016-08-04
_cRECORD # : i12933946
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
999 _c113591
_d113591