000 03834nam a2200409 4500
005 20260818223258.0
008 290998s1994 th r 0000|0 eng d
035 _a.b11407074
099 9 _aAIT Thesis no. ET-94-11
100 0 _aNguyen Hung Quoc
245 1 2 _aA study on the electrical energy requirements in a spinning factory in Vietnam
260 _aBangkok :
_bAsian Institute of Technology,
_c1994
300 _a78 leaves +1 online resource
490 1 _aThesis ;
_vno. ET-94-11
500 _aA thesis submitted in partial fulfillment of the requirement for the degree of Master of Engineering
502 _aThesis (M.Eng.) - Asian Institute of Technology, 1994
520 _aThis study was performed in order to determine the electricity conservation potential in a chosen spinning mill in Vietnam - the Hanoi Combined Spinning and Knitting Enterprise (HANOSIMEX). Attention was focused on the operation of air-conditioning system inside the mill. It was found that a significant saving of electricity can be obtained by using the open air loop operation of air washer within Hanoi weather conditions. The existing operation of airconditioning system at HANOSIMEX seems inefficient and sometimes causes negative saving in electricity consumption, due to the improperly chosen controlling method. A new operation procedure was proposed, which helps to reduce the energy consumption by almost 50%. A computer program was written in FoxPRO to facilitate the calculations. It was used to define the energy consumption and energy saving of different modes of air-conditioning system operation. The results are given in the form of daily, monthly, and annual calculations. The results indicate that OPEN-loop operation can be benefit only if the control indicator is enthalpy of air, but not temperature. Energy savings in the range of 10 to 50% are theoretically possible for air-conditioning system at HANOSIMEX. The evaluation of both technical and economic potential saving of cogeneration application was performed for existing and proposed operation modes of air conditioning system with different scenarios. The results of analysis reveal that cogeneration with double effect absorption chillers can be attractive with the existing subsidized electricity costs, if the scenario of power matching was used. Cogeneration potential can be greatly increased if the electricity cost is at the level of 550 d/kWh (about 5 cent/kWh). In combination with the proposed operation mode of air conditioning system, cogeneration will give extra saving in energy and money, compared with the proposed operation alone.
650 1 0 _aElectric power consumption
_xVietnam
_xForecasting
700 0 _aSurapong Chiraratananon,
_eChairperson
700 1 _aBhattacharya, Sribas C.,
_eExamination Committee
700 1 _aChen, Xavier,
_eExamination Committee
710 2 _aThe Government of France,
_eScholarship Donor
810 2 _aAsian Institute of Technology.
_tThesis ;
_vno. ET-94-11
856 _3Full-Text
_u http://203.159.5.9/ait-thesis/detail.php?q=B16225
907 _a.b11407074
_bmnait
_cx
902 _a240403
998 _b2
_c951104
_dm
_ea
_fx
_g2
945 _lmnait
945 _lmnait
945 _lmnarc
942 _c20
942 _c40
909 _aBarcode : 30050003107389
_bCREATED : 1994-07-06
_cRECORD # : i11649884
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : 30050002933397
_bCREATED : 1994-07-06
_cRECORD # : i11649896
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : 30050120367221
_bCREATED : 2016-06-13
_cRECORD # : i13033244
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
999 _c115373
_d115373