000 03978cas|a2200433 i 4500
005 20260819085201.0
008 170399s1992 th u m rtt 0| a1eng d
035 _a.b10743054
099 9 _aAIT Thesis no.EV-92-18
100 1 _aAlam, Md. Ashraful
245 1 0 _aTreatment alternatives for sludge handling in water treatment plant, Bangkok
260 _aBangkok :
_bAsian Institute of Technology,
_c1992
300 _a110 p.
490 1 _aThesis ;
_vno. EV-92-18
500 _aA thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering
502 _aThesis (M.Eng.) - Asian Institute of Technology, 1992
520 _aThis study was aimed to investigate the use of Crossflow Microfiltration (CFMF) to treat the filter backwash wastewater and Vacmun Assisted Sludge Dewate1ing Bed (VASDB) and Filter Press to treat the clarifier sludge generated from Bangkhan Water Treatment Plant of the Metropolitan Water Works Authority (MWA), Thailand. Crossflow Microfiltration (CFMF) is a pressure driven membrane process allowing better permeate flux by shearing action of flow. It can remove most of the suspended solids present in water and wastewater. Periodic backflash was used as a de-clogging technique to minimize the declining flux resulting from membrane surface deposition and intemal pore clogging. In this study, different sets of CFMF experiments were carried out for raw, settled, flocculation with settling of backwash wastewater. Vacuum Assisted Sludge Dewatering Bed (VASD B) and Filter Press were used for dewatering the sludge generated from clarifiers. Capillary Suction Time (CST) test revealed the optimum dosages of Magnafloc LT 26, an anionic polyelectrolyte to be 0.06 %TS. VASDB works with the combined application of gravity and vacuum pressure. The optimum slt1dge2 toading rate found from VASDB expeiiments for vacuum applied conditioned sludge was 15 kg/(m .d). The cake solid content for conditioned sludge with vacuum application, conditioned sludge without vacuum application and non conditioned sludge without vacuum application were 21.9, 10.2 and 3.9 %TS, respectively at the optimum sludge loading rate. Results from pilot scale filter press study showed that a filtration time of 4 hours is necessary to produce a sludge cake containing more than 30 %TS. The filtrates were clear and light yellowish in color having average SS and turbidity of 25 mg/l and 25 NTU, respectively. A cost comparison between VASDB, Sand Drying Beds and Filter Press indicated that VASDB system is a more cost- effective systems.
650 1 0 _aWater treatment plants
_zThailand
_zBangkok
650 1 0 _aSewage
_xPurification
_xActivated sludge process
700 0 _aSamorn Muttamara,
_eChairperson
700 1 _aVisvanathan, C.,
_eExamination Committee
700 1 _aMora, J. C.,
_eExamination committee
700 0 _aSompol Boonthanon,
_eExamination committee
710 2 _aCanadian International Development Authority (CIDA),
_eScholarship donor
810 2 _aAsian Institute of Technology.
_tThesis ;
_vno. EV-92-18
856 _3Full-Text
_u http://203.159.5.9/ait-thesis/detail.php?q=B16652
907 _a.b10743054
_bmnait
_cx
902 _a240403
998 _b2
_c951012
_dm
_ea
_fx
_g0
945 _lmnait
945 _lmnait
945 _lmnarc
942 _c20
942 _c40
909 _aBarcode : 30050003046728
_bCREATED : 1994-05-19
_cRECORD # : i10953152
_dLPATRON : 1019739
_eLCHKIN : 2006-01-11
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 1
_jTOT RENEW : 0
909 _aBarcode : 30050003046736
_bCREATED : 1994-05-19
_cRECORD # : i10953164
_dLPATRON : 1009869
_eLCHKIN : 1998-01-05
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 1
_jTOT RENEW : 0
909 _aBarcode : 30050160056098
_bCREATED : 2016-11-05
_cRECORD # : i12974791
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
999 _c122970
_d122970