245 1 0 _aBiokinetics and performance studies on attached growth membrane bioreactor for polluted surface water treatment
260 _aPathum Thani, Thailand :
_bAsian Institute of Technology,
_c2016
300 _a101 p. :
_bill. +
_e1 online resource
490 1 _aThesis ;
_vno. EV-16-18
500 _aA thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering in Environmental Engineering and Management
502 _aThesis (M.Eng.) - Asian Institute of Technology, 2016
520 _aA novel attached growth membrane bioreactor process was investigated for treatment of the polluted surface water with CODMn approximately 10 mg/Las a raw water in drinking water production. Firstly, Aquaporousgel (APG) and Polyvinyl alcohol gel (PVA-Gel) were compared to select the suitable carrier. According to pollutants removal and Monod{u2019}s kinetic coefficients analysis, PVA-Gel was the most suitable carrier with CODMn removal of 79% and NH3-N removal of 67.13%. Growth yield, maximum specific growth rate, half velocity constant and microbial decay rate of the PVA-Gel were 0.4999 gVSS/gCOD, 0.048 d-1, 9.923 mgCODMn/L, 0.00145 d-1 respectively. Secondly, six different filling ratio of PVA-Gel(5, 10, 15, 20, 30, and 50%) were applied in batch moving bed reactors. 15% filling ratio showed the appropriate performance among others with 72.08% of CODMn removal and 47.65% of NH3-N removal. As a results of preliminary studies, two laboratory scale reactors; attached growth membrane bioreactor with 15% PVA-Gel and conventional membrane filtration reactor with a submerged polytetrafluoroethylene hollow fiber membrane module with the pore size of 0.1 om were conducted. As compared to membrane filtration process, attached growth membrane bioreactor achieved two times higher CODMn removal with 54.1±10.5%. Almost complete ammonia removal was occurred with 84.7% by membrane filtration and 95.6% by attached growth membrane bioreactor. Turbidity was completely removed. However, UV254 removal was still low around15-20% in both reactors. For fouling study, attached growth membrane bioreactor showed the greater ability to reduce membrane fouling rate which correlated to the slower increasing of transmembrane pressure and longer operation period. The fouling layer was still proved to be a biofouling from the membrane resistance analysis. Hydraulic retention time at 2 hours was selected to be the most suitable operational condition by providing the greatest performance and constant effluent concentration. Lastly, Modified Stover-Kincannon model was a preferable model to apply for attached growth membrane bioreactor system with R2>0.92 in order to predict the treatment plant performance both CODMn and NH3-N removal, control the operational condition and optimize the plant volume design.
650 0 _aWater quality management
650 0 _aWater
_xPurification
_xMembrane filtration
700 1 _aVisvanathan, C.,
_eChairperson
700 1 _aAnnachhatre, Ajit P.,
_eExamination Committee
700 1 _aShipin, Oleg V.,
_eExamination Committee
710 2 _aThailand (HM Queen),
_eScholarship Donor
810 2 _aAsian Institute of Technology.
_tThesis ;
_vno. EV-16-18
856 _3Full-Text
_uhttp://203.159.5.9/ait-thesis/detail.php?q=B02641
907 _a.b12303574
_bmnait
_ct
902 _a240423
998 _b0
_c190402
_dm
_ea
_ft
_g0
962 _a000:001:PDF:b1230357:004039:0:0:0:0:0:0
_tClick to view Abstract
_vn
945 _lmnait
945 _lmnait
945 _lmnarc
942 _c21
942 _c40
909 _aBarcode : 30050120546592
_bCREATED : 2019-02-04
_cRECORD # : i1317017x
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : 30050120546568
_bCREATED : 2019-02-04
_cRECORD # : i13170181
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 1
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : 30050120877989
_bCREATED : 2019-06-20
_cRECORD # : i13195359
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
999 _c12357
_d12357