000 03316nam a2200385 4500
005 20260819090240.0
008 th eng
035 _a.b11700233
099 9 _aAIT Thesis no.ET-97-33
100 0 _aDang Hoang An
245 1 0 _aVoltage control in power systems :
_ba case study of Vietnam
260 _aBangkok :
_bAsian Institute of Technology,
_c1997
300 _a202 leaves +
_e1 online resource
490 1 _aThesis ;
_vno. ET-97-33
500 _aA thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering
502 _aThesis (M.Eng.) - Asian Institute of Technology, 1997
520 _aVoltage control problem in power systems is one of the most important aspects of modern power system operation and planning. Voltage is one of the basic parameters indicating the quality of supplied energy. Optimization of voltage and reactive power, together with economic load dispatch, ensures not only minimum cost but also reliable and secure operation of the system. The aim of the present study is to critically assess the voltage situation in Vietnam power system network and to find measures to solve its inherent voltage problem. Analysis of present voltage/reactive power controlling practices is carried with the help of load flow studies for different operating scenarios. Optimal Power Flow (OPF) has been utilized to exploit the available reactive power resources to overcome voltage problem. Problem of reactive power planning has been studied for situations before and after the application of Optimal Power Flow. Optimal Power Flow is used popularly by electric utilities around the world to ensure the optimal combination of existing voltage/reactive power controlling devices before considering the installation of new devices. This allows utilities to avoid considerable investment. It has been found that Optimal Power Flow can be utilized to decide the optimal settings of generators and transformer tappings in the daily operation of Vietnam power system. Although OPF could not solve the voltage problem in the network completely, it helps in reducing the transmission loss. Further measures, such as installation of new capacitors have been suggested to mitigate the voltage problem.
650 1 0 _aElectric power systems
_xVietnam
_xControl
700 1 _aSrivastava, Suresh Chandra,
_eChairperson
700 0 _aSurapong Chiraratananon,
_eExamination Committee
700 1 _aMalik, Arif Saeed,
_eExamination committee
710 2 _aSwedish International Development Authority (SIDA),
_eScholarship donor
810 2 _aAsian Institute of Technology.
_tThesis ;
_vno. ET-97-33
856 _3Full-Text
_uhttp://203.159.5.9/ait-thesis/detail.php?q=B13728
907 _a.b11700233
_bmnait
_cy
902 _a240403
998 _b0
_c980410
_dm
_ea
_fy
_g0
945 _lmnait
945 _lmnarc
942 _c22
942 _c40
909 _aBarcode : 30050120713184
_bCREATED : 2014-04-02
_cRECORD # : i12756672
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : 30050120366066
_bCREATED : 2016-06-14
_cRECORD # : i13036245
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
999 _c127061
_d127061