000 04164cas a2200421 a 4500
005 20260817171620.0
008 110910s1986 th uu|m rtt 0| a1eng d
035 _a.b10024190
099 9 _aAIT Thesis no. AE-86-10
100 1 _aBorhan, Md. Saidul
245 1 2 _aA blower for chopped water hyacinth
260 _aBangkok :
_bAsian Institute of Technology,
_c1986
300 _a73 p.
490 1 _aThesis ;
_vno. AE-86-10
500 _aA research study submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Environment, Resources and Development
502 _aThesis (M.Eng.) - Asian Institute of Technology, 1986
520 _aA blower was developed, tested and evaluated for blowing of chopped water hyacinth. The diameter of the blower was 0. 70 m, width 0. 23 m and the thickness of the casing was 3 mm. Six radial blades of 4 mm thickness were fixed with blade-arm of 0.275 m long 38.1x6 .35mm angle bar. These angle bars were bolted to the back plate of thickness 20 mm . A conveyor was used to feed the material directly into the blower. Blowing operation was done at different speeds, inclination and feed rates. At 45 degree inclination the maximum distance of throw was found to be 19 . 9 m and minimum was 3 . 5 and width of the thrown material on the floor was 1. 5 meter. Distance of throw was measured at 1 meter interval along the horizontal direction to observe distribution of thrown hyacinth Regression analysis of the total peak power requirements of two components for blowing chopped water hyacinth was done . The two components were : (1) total power requirement for operating the blower at no- load condition, and (2) total peak power for blowing chopped hyacinth. The total power requirement for operating the blower at no-load condition consists of : (a) power for operating the blower motor, (b) power for air movement and (c) power losses from shaft, bearing , bush friction and windage losses . Total peak power for blowing chopped water hyacinth consists of (1) power requirement for overcoming friction between hyacinth and housing of the blower, and (2) power requirement for blowing (accelerating) water hyacinth . Effect of cutting lengths as well as effect of moisture content on power requirement was ascertained. Fresh water hyacinth(88 . 2% wb) was chopped in three different sizes (10.26 cm, 6.43 cm and 4.64 cm) for blowing . Trials were conducted with sun dried ( 13 . 31% moisture content) and partially dewatered (85 . 76 % moisture content, wd) hyacinth. The capacity of the machine was 10.8 tons/ hour at 180 kg/ min feed rate and at 1002 RPM . The peak power consumption in blowing was 7. 23 kW with equivalent amount of energy of o . 67 kW-hr/ton (2 .41 mJ/t). The overall efficiency of the blower was 20 . 35 %. Further testing of the blower with the harvester is required under field conditions.
650 0 _aHyacinths
650 0 _aFans (Machinery)
700 1 _aGee-Clough, D.,
_eChairperson
700 1 _aGupta, Chandra P.,
_eExamination Committee
700 1 _aSingh, Gajendra,
_eExamination Committee
710 2 _aCanadian International Development Agency (ClDA),
_eScholarship Donor
810 2 _aAsian Institute of Technology.
_tThesis ;
_vno. AE-86-10
856 4 0 _3Full-Text
_uhttp://203.159.5.9/ait-thesis/detail.php?q=B19571
907 _a.b10024190
_bmnait
_cs
902 _a240409
998 _b2
_c951012
_dm
_ea
_fs
_g2
945 _lmnait
945 _lmnait
945 _lmnarc
942 _c20
942 _c40
909 _aBarcode : 30050003001418
_bCREATED : 1994-05-16
_cRECORD # : i1000497x
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : 30050003001442
_bCREATED : 1994-05-16
_cRECORD # : i10004981
_dLPATRON : 1011893
_eLCHKIN : 1998-02-13
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 3
_jTOT RENEW : 0
909 _aBarcode : 30050120300230
_bCREATED : 2016-05-27
_cRECORD # : i12996543
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
999 _c12931
_d12931