000 04023nam a2200433 4500
005 20260817171628.0
008 011298s1988 th r 0000|00eng d
035 _a.b10118603
099 9 _aAIT Thesis no. EV-88-3
100 1 _aSitaramamurty, Bhamidipati
245 1 0 _aBOD5, COD and solids removal in a facultative pond and a water hyacinth pond :
_ba case study
260 _aBangkok :
_bAsian Institute of Technology,
_c1988
300 _a68 p.
490 1 _aThesis ;
_vno. EV-88-3
500 _aA thesis submitted in partial fulfilment of the requirement for the degree of Master of Engineering, School of Environment, Resources and Development
502 _aThesis (M.Sc.) - Asian Institute of Technology, 1988
520 _aExperiments were conducted in two stages, namely before increase of load and after increase of load on water hyacinth pond. In the first stage comparison was made between facultative pond performance and water hyacinth pond performance in removing BOD5,COD,SS and TS, where as in the second stage removal efficiency and the effect of high loading on water hyacinth was studied. Experiments were performed from October 1 5, 1 987 to December 9, 1 987 in the first stage and from December 12, 19 87 to February 28, 1 988 in the 2nd stage . The existing set of parallel oxidation ponds which are treating the wastewater from AIT campus were used in t hi s study. Hyacinth pond showed better performance compared to facultative pond even after two years of harvesting. During the period of observation the average effluent concentrations in the water hyacinth pond were 1 2, 38, 7 and 631 mg/L for BOD5, COD, SS and TS respectively, where as the corresponding values in the facultative pond were 1 4, 5 1 , 36 and 667 mg/L respectively. Mean COD loadings to the system were 83 kg/Cha. d)and 78 kg/Cha. d) for water hyacinth and facultative pond respectively. The mean mass of BOD5, COD, SS and TS were re moved at 76, 62, 85 and 26 % respectively in the hyacinth pond , where as in the facultative pond, mass BOD5, COD, SS and TS were removed at 73, 49, 33 and 24 % respectively. In the second stage when the load was 18 1 2 m3/Cha . d) as compared to the first stage load 1002 m3/Cha. d), the effluent BOD5, COD, SS and TS concentrations were 17, 47, 3 and 648 mg/L respectively. Th e mean COD loading in the second stage was 1 50 kg/Cha. d) as compared to 83 kg/( h a. d) in the first stage. The mean mass of BOD5, COD, SS and TS were removed at 76, 6 1, 85 and 35 % respectively in the second stage as compared to 76, 62, 85 and 26 % for BOD5, COD, SS and TS respectively in the first stage . This shows that the water hyacinth performance was quite good even after increase of loading.
650 0 _aSewage lagoons
650 0 _aSewage
_xPurification
_xBiological treatment
650 0 _aHyacinths
700 1 _aOrth, Hermann M.,
_eChairperson
700 1 _aI, Fude,
_eExamination Committee
700 0 _aSamorn Muttamara,
_eExamination Committee
710 2 _aThe Royal Norwegian Government,
_eScholarship Donor
810 2 _aAsian Institute of Technology.
_tThesis ;
_vno. EV-88-3
856 _3Full-Text
_uhttp://203.159.5.9/ait-thesis/detail.php?q=B18873
907 _a.b10118603
_bmnait
_cx
902 _a240411
998 _b2
_c951012
_dm
_ea
_fx
_g0
945 _lmnait
945 _lmnait
945 _lmnarc
942 _c20
942 _c40
909 _aBarcode : 30050003044186
_bCREATED : 1994-05-16
_cRECORD # : i10133483
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : 30050003044194
_bCREATED : 1994-05-16
_cRECORD # : i10133495
_dLPATRON : 1017687
_eLCHKIN : 2005-07-03
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 11
_jTOT RENEW : 11
909 _aBarcode : 30050120223622
_bCREATED : 2016-10-05
_cRECORD # : i12973397
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
999 _c12979
_d12979