000 04684nas a2200397 a 4500
005 20260817161457.0
008 220210 2020 th uu m rtt 0| a1eng
035 _a.b12378975
099 9 _aAIT Thesis no.ST-20-03
100 0 _aPhasuthorn Phiwphong
245 1 0 _aActive control of aerodynamic flow around structures by using plasma actuators
260 _aPathum Thani, Thailand :
_bAsian Institute of Technology,
_c2020
300 _a126 leaves :
_bill.
490 1 _aThesis ;
_vno. ST-20-03
500 _aA thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering in Structural Engineering, School of Engineering and Technology
502 _aThesis (M. Eng.) - Asian Institute of Technology, 2020
520 _aThe main goal of this research is to study the performance of plasma actuators on the aerodynamic force. The circuits which used to drive the plasma actuators were developed at the Nuclear Engineering Department of Chulalongkorn University, which consists of high voltage circuits at a low-frequency range and high voltage circuits at a high-frequency range. The specimen was studied under two basic shapes configuration models which include cylinder and square that the measurement aerodynamic force techniques were included the high-frequency force balance (HFFB) technique and the high-frequency pressure integration (HFPI). This thesis was conducted on free-stream flow conditions at varying wind speeds inside the TU-AIT wind tunnel. From the result of plasma actuators by using high voltage circuits at low-frequency range, for a cylinder model, it was found that the plasma actuators are efficient in reducing the drag force at 1.7 m/s (low wind speed) up to 27%, while the square model can reduce the drag force by 9%. Also, the plasma actuators can effectively streamline in the across-wind flow which can reduce the formation of vortex shedding, as shown by the PSD peak. For cylinder model, the PSD peak is reduced up to 50% at 1.7m/s (low wind speed). at higher wind speed, the plasma actuators are still to reduce the PSD peak by 17-20%. For square model, the PSD peak is reduced up to 27% at 1.7m/s (low wind speed). From the results, the plasma actuators which are driven by high-voltage at low frequency range circuits be effective in the area of low wind speed. The plasma actuators which are driven by high-voltage circuits at the high-frequency range (HF circuit) are better effective in reducing drag force. For cylinder model has the most efficiency at 1.7 m/s (low wind speed) by up to 52%. At higher wind speed, the plasma actuators are also effective which reduces the drag coefficient by 32%, 16% and 13% at wind speed 3.5m/s, 4.9 m/s and 7.1 m/s respectively. For the square model, the plasma actuators did not perform well to reduce the drag force. In addition, the plasma actuators which driven by the HF circuit help to reduce the formation of the Vortex shedding better than the LF circuit. For the cylinder model, the maximum drop is up to 92% at a wind speed of 1.7 m/s. Also, at higher wind speeds, the PSD Peak reduces up to 36-43%. For square model, the peak of PSD reduces by 54% at 1.7m/s (low wind speed). At higher wind speed the plasma actuators are still to reduce the PSD peak by 14-17% From the testing results, the circuit which is driven by high voltage circuit at the high-frequency range (HF circuit) help to control the flow by improving the airflow around the model that works best in reducing the mean drag force. Moreover, it also helps to reduce the formation of Vortex shedding, which causes structural vibrations.
650 0 _aWind tunnels
_xFlow visualization
650 0 _aplasma actuators
700 0 _aPennung Warnitchai,
_eChairperson
700 0 _aPunchet Thammarak,
_eExamination Committee
700 0 _aRaktipong Sahamitmongkol,
_eExamination Committee
710 2 _aRoyal Thai Government Fellowship,
_eScholarship Donor
810 2 _aAsian Institute of Technology.
_tThesis ;
_vno. ST-20-03
856 _3Full-Text
_uhttp://203.159.5.9/ait-thesis/detail.php?q=B15720
907 _a.b12378975
_bmnait
_cm
902 _a240419
998 _b0
_c220210
_dm
_ea
_fm
_g0
945 _lmnarc
945 _lmnarc
942 _c67
942 _c40
909 _aBarcode : -
_bCREATED : 2022-10-02
_cRECORD # : i13364595
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : 30020220004876
_bCREATED : 2023-10-01
_cRECORD # : i13423691
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
999 _c1452
_d1452