| 000 | 03067cas a2200385 a 4500 | ||
|---|---|---|---|
| 005 | 20260817172058.0 | ||
| 008 | 230998s1981 th uu|m rtt 0| a1eng d | ||
| 035 | _a.b10126661 | ||
| 099 | 9 | _aAIT Thesis no.AE-81-04 | |
| 100 | 1 | _aButlig, Felipe Tancio | |
| 245 | 1 | 0 | _aCalibration and performance evaluation of a vane-in-a-pipe : a water measuring device for partly filled pipes |
| 260 |
_aBangkok : _bAsian Institute of Technology, _c1981 |
||
| 300 | _a69 p. | ||
| 490 | 1 |
_aThesis ; _vno. AE-81-04 |
|
| 500 | _aA thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Environment, Resources and Development | ||
| 502 | _aThesis (M.Eng.) - Asian Institute of Technology, 1981 | ||
| 520 | _aThree sizes of the vane-in-a-pipe flow measuring device (VIP) were tested at the Hydraulics laboratory of the Asian Institute of Technology. The sizes of VIP tested were 25.4 cm, 30.5 cm, and 38.1 cm, each having a length of 100 cm. These are equivalent to the standard sizes of reinforced concrete pipes (culverts) available in the market. Results of the study showed that the approach and exit flow conditions did not significantly affect the discharge through the device. Likewise, the variations of submergence ratios, did not significantly affect the discharge. Furthermore, discharges calculated using the theoretical equations of the three sizes of VIP did not significantly differ from the discharges calculated using the set of statistically derived discharge equations. All these parameters were tested at the 95% confidence interval as recommended by the International Standards Organization (ISO). Another significant result of the study showed the independence of the moment to variations in velocity for a given discharge. The VIP device is suitable in measuring flow with low velocity and flat gradient channels. It is not suggested as a blanket replacement for other flow measuring devices. Instead, it could serve as a valuable addition to the researchers list of tools complementing the traditional weirs and flumes. | ||
| 650 | 0 |
_aFlow meters _xCalibration |
|
| 700 | 0 |
_aApichart Anukularmphai, _eChairperson |
|
| 700 | 0 |
_aPrida Thimakorn, _eCo-Chairperson |
|
| 700 | 1 |
_aOlesen, Svend Elsnab, _eExamination Committee |
|
| 710 | 2 |
_aGovernment of Australia, _eScholarship Donor |
|
| 810 | 2 |
_aAsian Institute of Technology. _tThesis ; _vno. AE-81-04 |
|
| 856 |
_3Full-Text _uhttp://203.159.5.9/ait-thesis/detail.php?q=B21507 |
||
| 907 |
_a.b10126661 _bmnait _cx |
||
| 902 | _a241213 | ||
| 998 |
_b2 _c951012 _dm _ea _fx _g0 |
||
| 945 | _lmnait | ||
| 945 | _lmnarc | ||
| 942 | _c22 | ||
| 942 | _c40 | ||
| 909 |
_aBarcode : 30050120584767 _bCREATED : 2013-10-06 _cRECORD # : i12731092 _dLPATRON : 0 _eLCHKIN : - _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 0 _jTOT RENEW : 0 |
||
| 909 |
_aBarcode : 30050120303515 _bCREATED : 2016-05-26 _cRECORD # : i12993396 _dLPATRON : 0 _eLCHKIN : - _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 0 _jTOT RENEW : 0 |
||
| 999 |
_c14727 _d14727 |
||