000 03848nam a2200385 4500
005 20260817173422.0
008 280998s1985 th r 0000|0 eng d
035 _a.b10151710
099 9 _aAIT Thesis no.ET-85-16
100 2 _aDe Silva, Induruwage Prabhath Darshana
245 1 0 _aComparison and application of simplified simulation procedures for solar heating systems
260 _aBangkok :
_bAsian Institute of Technology,
_c1985
300 _a119 p.
490 1 _aThesis ;
_vno. ET-85-16
500 _aA thesis submitted in partial fulfillment of requirements for the degree of Master of Engineering, School of Environment, Resources and Development
502 _aThesis (M.Eng.) - Asian Institute of Technology, 1985
520 _aSinusoidal representation of the monthly mean diurnal variation of solar radiation for both horizonal and for equator facing tilted surfaces is proposed. The sinusoidal functions so constructed are found to give very good agreement with the empirical correlations suggested by Collares-Pareira and Rabl, from actual data. Consequently, the necessity of using complex correlations for transforming horizontal radiation onto tilted surfaces is reduced. Also a new procedure to determine the optimum angle of equator facing tilted collectors has been proposed, which can be applied to any time periods. (month, season of year) The single equation suggested, fits very well with the recommendation given by Evans. For widespread applications of solar energy, it is essential to have design methods by which solar energy installations can be sized rationally with a minimum of computational effort and expense. Though several such design methods have already been proposed, they are either system or load specific and cannot be used as versatile design methods. Two new methods, namely MIRA developed by Reddy and TMD Proposed by Feuermann et al. are presented, Compared and analysed for a wide range of system configurations and load patterns with existing radiation data for Bangkok. The predictions by both these methods are in good agreement with the hour by hour detailed simulation over the total time period and also with those of the o-f Chart method. For an example, in the hot water load considered in RUN 1, MIRA is within 2% of detailed simulation results and TMU is within about 4% but these figures change with the different input parameters. The methods require very little computational effort and data base as compared to standard detailed hour by hour computer simulation, while at the same time yielding the relevant system performance data required for solar system sizing. For certain RUNS, detailed simulation consumed about 60 times more CPU time, than TMD and MIRA do. The applications and the reliability for various input parameters (like storage volume, diurnal load pattern etc.) are also discussed
650 0 _aSolar heating
_xSimulation methods
700 1 _aReddy, T. A.,
_eChairperson
700 0 _aPrida Wibulswas,
_eExamination Committee
700 1 _aLasnier, France,
_eExamination Committee
710 2 _aCanadian International Development Authority
810 2 _aAsian Institute of Technology.
_tThesis ;
_vno. ET-85-16
856 _3Full-Text
_uhttp://203.159.5.9/ait-thesis/detail.php?q=B19998
907 _a.b10151710
_bmnait
_cx
902 _a240411
998 _b2
_c951012
_dm
_ea
_fx
_g0
945 _lmnait
945 _lmnarc
942 _c22
942 _c40
909 _aBarcode : 30050120679104
_bCREATED : 2014-12-02
_cRECORD # : i12762453
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : 30050120353114
_bCREATED : 2016-06-15
_cRECORD # : i13038941
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
999 _c19848
_d19848