245 1 2 _aA comparison between HFFB and HFPI techniques for determining wind-induced response of tall buildings
260 _aPathum Thani :
_bAsian Institute of Technology,
_c2013
300 _a1 online resource (111 leaves) :
_bill. (some col.), charts
490 1 _aThesis ;
_vno. ST-13-09
500 _aA thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering in Structural Engineering, School of Engineering and Technology
502 _aThesis (M. Eng.) - Asian Institute of Technology, 2013
520 _aThe present study has been conducted in order to study and develop the wind tunnel test methods (HFFB and HFPI techniques) on tall building models for the TU-AIT wind tunnel. Both techniques were carried out to compare in both wind-induced forces and responses. The experiments of both methods were performed on two tall buildings{u2019} models such as simple (standard CAARC building) and complex (Overseas Union Bank Centre building) shape model. In comparative procedure, the verification of the HFPI measurement is the first step by comparing with the HFFB result in both simple and complex shape models. Then, the verification of correction factors for HFFB was carried out. The correction factors have been proposed by Holmes (J.D.Holmes, 1987) to correct the linear mode shape limitation of HFFB technique. When the both methods can provide the appropriate results, the determination of wind-induced responses would be conducted. In determining the responses, the various effects can be investigated that are the effect of correlation among the forces in different axis, the effect of the higher mode and the effect of the coupled mode analysis. For both simple and complex shape buildings, the results obtained from HFFB and HFPI methods have good agreement with also being compatible with earlier works. Moreover, the mode shape correction factors of HFFB method are successful to approximate the modal force under analyzing non-linear mode shape. In comparative responses, it seems that, in the CAARC building, the correlation and the higher mode have no significant effects on the responses. However, in the modified CAARC building (the standard CAARC building that was modified the structural properties having unsymmetrical stiffness system), the coupled mode analysis affects significantly on both displacement and acceleration. Lastly, in both coupled and uncoupled analyses, the extreme response of the building can be determined by using both methods with good agreement.
650 0 _aWind tunnels
_xTesting
650 0 _aTall buildings
700 0 _aPennung Warnitchai,
_eChairperson
700 0 _aThanakorn Pheeraphan,
_eExamination Committee
700 0 _aPunchet Thammarak,
_eExamination Committee
710 2 _aRoyal Thai Government,
_eScholarship Donor
710 2 _aAIT Fellowship,
_eScholarship Donor
810 2 _aAsian Institute of Technology.
_tThesis ;
_vno. ST-13-09
856 _3Full-Text
_uhttp://203.159.5.9/ait-thesis/detail.php?q=B04015
907 _a.b12134065
_bmnait
_cj
902 _a240404
998 _b0
_c140619
_dm
_ea
_fj
_g2
962 _a000:001:PDF:b1213406:001554:0:0:0:0:0:0
_tAbstract--AIT Thesis no.ST-13-09
_vn
945 _lmnait
945 _lmnait
945 _lmnarc
945 _lmnarc
942 _c20
942 _c40
942 _c67
909 _aBarcode : 30050120304224
_bCREATED : 2014-06-19
_cRECORD # : i1281345x
_dLPATRON : 1026886
_eLCHKIN : 2017-02-05
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 1
_iTOT CHKOUT : 2
_jTOT RENEW : 1
909 _aBarcode : 30050120818207
_bCREATED : 2014-06-19
_cRECORD # : i12813461
_dLPATRON : 1026886
_eLCHKIN : 2016-10-26
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 1
_jTOT RENEW : 1
909 _aBarcode : 30050120401178
_bCREATED : 2017-09-10
_cRECORD # : i13106703
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : -
_bCREATED : 2020-01-31
_cRECORD # : i13254327
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
999 _c19859
_d19859