| 000 | 03760nas a2200445 4500 | ||
|---|---|---|---|
| 005 | 20260817173433.0 | ||
| 008 | 011298s1985 th r 000| 0eng d | ||
| 035 | _a.b10151849 | ||
| 099 | 9 | _aAIT Thesis no.EV-85-28 | |
| 100 | 0 | _aYossarin Bhimsakka | |
| 245 | 1 | 0 | _aComparison of declining rate coarse media filtration with constant rate dual media filtration at Bangkhen water treatment plant |
| 260 |
_aBangkok : _bAsian Institute of Technology, _c1985 |
||
| 300 | _a115 p. | ||
| 490 | 1 |
_aThesis ; _vno. EV-85-28 |
|
| 500 | _aA thesis submitted in partial fulfillment of the requirements for the degree of Master of Science, School of Environment, Resources and Development | ||
| 502 | _aThesis (M.Sc.) - Asian Institute of Technology, 1985 | ||
| 520 | _aBangkhen Water Treatment Plant used dual media filter to remove the suspended solids from the effluent of solid-contact clarifier. The dual media filters used contains 80 cm of anthracite (E.S. = 0.85 mm; U = 1.5) over 40 cm of sand (E.S. + 0.5 mm, U = 1.5) at a filtration rate of 13.75 m3/m2.h. In this study the possibility of using narrowly graded sand as sole filter medium was investigated. The two sand sizes studied (1.00 to 1.19 mm; 1.19 to 1.41 mm and 1.20 m depth) indicated that the narrowly graded coarse medium produces comparable filter quality while leading to less headloss development. In this case the headloss was found to be more uniformly distributed especially when high filtration rates (>15 m3/m2.h) were used. The backwash velocity computation made for single coarse medium and dual media filters indicated that the former required much higher backwash rate than the latter for comparable degree of expansion. The declining rate filter experiments conducted with single medium filters indicated that the headloss development is lesser in the case of declining rate filtration compared to constant rate filtration for the same water production. This indicates the declining rate filtration can be operated for a longer time before backwashing which will reduce the significantly the operating cost of filter. The headloss equation H/Ho = 1+KO is found to be valid for constant rate filters and the value of K decreased with the increase in filtration rate and increase in sand size. The prediction of headloss for declining rate filters was satisfactory when using the K value of the average (both arithmetic and geometric means) velocity. | ||
| 650 | 0 |
_aWater treatment plants _xThailand _xBangkok |
|
| 650 | 0 | _aFilters and filtration | |
| 700 | 1 |
_aVigneswaran, S., _eChairperson |
|
| 700 | 0 |
_aSamorn Muttamara, _eExamination Committee |
|
| 700 | 1 |
_aLohani, B.N., _eExamination Committee |
|
| 710 | 2 |
_aFederal Republic of Germany (CDG), _eScholarship Donor |
|
| 810 | 2 |
_aAsian Institute of Technology. _tThesis ; _vno. EV-85-28 |
|
| 856 |
_3Full-Text _uhttp://203.159.5.9/ait-thesis/detail.php?q=B20027 |
||
| 907 |
_a.b10151849 _bmnait _cx |
||
| 902 | _a240411 | ||
| 998 |
_b2 _c951012 _dm _ea _fx _g0 |
||
| 962 |
_a000:001:PDF:b1015184:004658:0:0:0:0:0:0 _tAbstract _vn |
||
| 945 | _lmnait | ||
| 945 | _lmnait | ||
| 945 | _lmnarc | ||
| 942 | _c22 | ||
| 942 | _c40 | ||
| 942 | _c20 | ||
| 909 |
_aBarcode : 30050120804330 _bCREATED : 2014-05-28 _cRECORD # : i12804307 _dLPATRON : 0 _eLCHKIN : - _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 0 _jTOT RENEW : 0 |
||
| 909 |
_aBarcode : 30050120224190 _bCREATED : 2016-09-05 _cRECORD # : i12972800 _dLPATRON : 0 _eLCHKIN : - _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 0 _jTOT RENEW : 0 |
||
| 909 |
_aBarcode : 30050121073778 _bCREATED : 2023-10-04 _cRECORD # : i13442612 _dLPATRON : 0 _eLCHKIN : - _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 0 _jTOT RENEW : 0 |
||
| 999 |
_c19896 _d19896 |
||