000 03949nas a2200397 a 4500
005 20260818090437.0
008 230726s2023 th uu m rtt 0| a1eng d
035 _a.b12409224
099 9 _aAIT Thesis no.GE-22-10
100 1 _aRana, Md. Sohel
245 1 0 _aDeterminations of the correction factor for undrained shear strength and internal friction angle empirical models from CPT data :
_ba case study of Bangladeshi soils
260 _aPathum Thani, Thailand :
_bAsian Institute of Technology,
_c2023
300 _a99 leaves :
_bill.
490 1 _aThesis ;
_vno. GE-22-10
500 _aA thesis submitted in partial fulfillment of the requirements for the degree of Master of Science in Geotechnical and Earth Resources Engineering
502 _aThesis (M. Sc.) - Asian Institute of Technology, 2023
520 _aIn situ subsurface testing methods like CPT and SPT are utilized worldwide to investigate the soil{u2019}s geotechnical properties. In Bangladesh, the utilization of CPT for both small and large projects is increasing day by day. The determination of soil parameters such as undrained shear strength (Su) and internal friction angle ({u03D5}) holds significant importance in the design of foundations. These parameters are obtained from laboratory tests of soil samples collected from the field during the SPT test. The CPT provides a range of Su values, comprising both the maximum and minimum limits. However, the challenge lies in determining the precise value that is suitable for design purposes. There is no direct correlation between laboratory tested soil parameters (Su and {u03D5}) and CPT data. In this study, the main goal is to determine the correction factor and establish empirical models of Su and {u03D5} for CPT to minimize cost and reduce time for Bangladeshi soils. This study first reviews the existing correlations between soil parameters and CPT in the literature. For the analysis required, 378 SPT boring points and 146 CPT data were collected from two organizations, LGED and RAJUK, in Bangladesh. All the collected data is classified and summarized into two categories: trained data sets and test datasets. Regression analyses are applied using trained data to determine the correction factor and develop empirical modes of Su and {u03D5} for CPT. Test datasets are employed on models to verify and validate the developed models. In this research, it is possible to find out the correction factor for CPT parameters and establish empirical models of Su and {u03D5} for CPT with reference to laboratory tested Su and {u03D5} for Bangladeshi soils. Any design engineer can apply this model to the design of a foundation without performing laboratory tests for soil parameters. The development of models will have a significant impact on society due to their potential to reduce the time required for laboratory testing and their economic design implications.
650 0 _aShear strength of soils
650 0 _aCorrections
_zBangladesh
650 0 _aSoil penetration test
_vCase studies
700 0 _aAvirut Puttiwongrak,
_eChairperson
700 1 _aKuo-Chieh Chao,
_eExamination Committee
710 2 _aLocal Government Engineering Department (LGED), Bangladesh,
_eScholarship Donor
810 2 _aAsian Institute of Technology.
_tThesis ;
_vno. GE-22-10
856 4 0 _3Full-Text
_uhttp://203.159.5.9/ait-thesis/detail.php?q=B19498
907 _a.b12409224
_bmnait
_cm
902 _a250411
998 _b0
_c230726
_dm
_ea
_fm
_g0
945 _lmnarc
945 _lmnarc
942 _c40
942 _c61
909 _aBarcode : 30050121040355
_bCREATED : 2023-07-24
_cRECORD # : i13457007
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : -
_bCREATED : 2023-07-24
_cRECORD # : i13457019
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
999 _c28102
_d28102