| 000 | 03883nam a2200445 4500 | ||
|---|---|---|---|
| 005 | 20260818090645.0 | ||
| 008 | 130598 th eng | ||
| 035 | _a.b11511114 | ||
| 099 | 9 | _aAIT Thesis no. AE-95-04 | |
| 100 | 0 | _aTrinh Xuan Duc | |
| 245 | 1 | 0 | _aDevelopment of a hand-held air-assisted electrostatic sprayer |
| 260 |
_aBangkok : _bAsian Institute of Technology, _c1995 |
||
| 300 |
_a72 leaves + _e1 online resource |
||
| 490 | 1 |
_aThesis ; _vno. AE-95-4 |
|
| 500 | _aA thesis submitted in partial fulfillment of requirement for the degree of Master of Engineering | ||
| 502 | _aThesis (M.Eng.) - Asian Institute of Technology, 1995 | ||
| 520 | _aSerious environmental and worker safety problems caused by overuse and off-target movement of toxic pesticides have led to the pressures to replace synthetic toxic pesticides with natural non toxic alternatives. However, these alternative materials are weak pesticides unless they are placed directly at the site of insect or disease activity. They are also often very expensive. In order to achieve desirable controlled levels and economic thresholds with environmentally "soft" pesticides, present application methods need to be improved, particularly regarding distribution of spray to leaf underside surfaces. In this conjunction, the development of air assisted electrostatic sprayer was conducted. Air delivery increases spray penetration and turbulence within the plant canopy. Electrostatic charging increases spray deposit level, reduces waste, and greatly improves spray distribution for better insect and disease control. The air assisted electrostatic spinning disc sprayer was tested in laboratory with soybean plants. When electrode voltage was maintained at 2.5 kV, the results indicated that ratio of deposition density of air assisted and non air assisted application at top, middle, bottom levels were 1.38, 1.37 and 1.5 fold respectively. Mean deposition on plant target increased 1.44 fold due to air assistance. The leaf underside deposition occupied 27% of the total deposition (increased 7% because of air assistance).The optimum tilt angle between disc plane and air stream direction found to be 105 degree. The improvement of structure brought about the reduction of 1.93 to 2.37 fold on power consumption. In spite of extra cost of battery and fan unit, break-even area for air assisted electrostatic sprayer was 0.43 ha as compared to the electrostatic sprayer. | ||
| 650 | 1 | 0 | _aSpraying equipment |
| 700 | 1 |
_aGupta, C.P., _eChairperson |
|
| 700 | 1 |
_aStevens, Willem Frans, _eExamination Committee |
|
| 700 | 1 |
_aSalokhe, Vilas M., _eExamination Committee |
|
| 700 | 1 |
_aUpasena, S.H., _eExamination committee |
|
| 710 | 2 |
_aSIDA, _eScholarship donor |
|
| 810 | 2 |
_aAsian Institute of Technology. _tThesis ; _vno. AE-95-4 |
|
| 856 |
_3Full-Text _uhttp://203.159.5.9/ait-thesis/detail.php?q=B14942 |
||
| 907 |
_a.b11511114 _bmnait _cv |
||
| 902 | _a250317 | ||
| 998 |
_b0 _c960709 _dm _ea _fv _g0 |
||
| 945 | _lmnait | ||
| 945 | _lmnait | ||
| 945 | _lmnarc | ||
| 945 | _lmnarc | ||
| 942 | _c20 | ||
| 942 | _c40 | ||
| 909 |
_aBarcode : 30050004034822 _bCREATED : 1995-09-02 _cRECORD # : i11798002 _dLPATRON : 0 _eLCHKIN : - _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 0 _jTOT RENEW : 0 |
||
| 909 |
_aBarcode : 30050004034798 _bCREATED : 1995-09-02 _cRECORD # : i11798014 _dLPATRON : 1011782 _eLCHKIN : 1999-07-03 _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 1 _jTOT RENEW : 0 |
||
| 909 |
_aBarcode : 30050120371850 _bCREATED : 2016-02-06 _cRECORD # : i13011327 _dLPATRON : 0 _eLCHKIN : - _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 0 _jTOT RENEW : 0 |
||
| 909 |
_aBarcode : 30050120914600 _bCREATED : 2019-11-22 _cRECORD # : i13232988 _dLPATRON : 0 _eLCHKIN : - _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 0 _jTOT RENEW : 0 |
||
| 999 |
_c28782 _d28782 |
||