| 000 | 03886nas a2200493 a 4500 | ||
|---|---|---|---|
| 005 | 20260818090706.0 | ||
| 008 | 210704s2021 th u m rtt 000 a eng d | ||
| 035 | _a.b12371993 | ||
| 099 | 9 | _aAIT Thesis no.EV-21-14 | |
| 100 | 0 | _aPitchaya Saetan | |
| 245 | 1 | 0 | _aDevelopment of a novel media for constructed wetlands systems for treating solar septic tank effluent |
| 260 |
_aPathum Thani, Thailand : _bAsian Institute of Technology, _c2021 |
||
| 300 |
_a94 leaves : _bill. |
||
| 490 | 1 |
_aThesis ; _vno. EV-21-14 |
|
| 500 | _aA thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering in Environmental Engineering and Management | ||
| 502 | _aThesis (M. Eng.) - Asian Institute of Technology, 2021 | ||
| 520 | _aThe solar septic tank which was an improvement of a conventional septic tank was regarded to be an effective on-site sanitation technology. However, the solar septic tank effluent does not still meet the national discharged standards of Thailand. Therefore, the post-treatment which is the constructed wetland is necessary for wastewater treatment to follow the Thailand standard. The vertical wetland in this experiment consists of the novel media, the appropriate type of plant, and vertical flow pattern. Moreover, these operating systems were installed with the building wall to overcome the limitations of huge area requirements. For the best media, they consist of zeolite, bentonite, laterite soil, and coffee ground. Its result of phosphorus concentration at 3, 6, 9 mg/L was 78.38, 89.60, and 94.28%, respectively. In terms of the optimum HRT, the highest value in this experiment of removal performance of COD, NH3-N, and TP is HRT of 36 hours. Finally, the comparison performance between types of plant in reactors present that M2, Coleus system provided the highest removal performance of COD, TKN, and TSS in phase 1. For the experiment in phase 2, the highest treatment capacity of COD, TSS, and VSS was M2, Coleus system. The consequence of the plant uptake capacity of TP and TN presents that M2, Coleus system was the highest performance. The most appropriate type of plant for the vertical wetland was Coleus which was installed in the M2 system. | ||
| 650 | 0 |
_aWastewater _xTreatment |
|
| 650 | 0 |
_aConstructed wetlands _zThailand |
|
| 650 | 0 |
_aSeptic tanks _zThailand _xManagement |
|
| 700 | 0 |
_aThammarat Koottatep, _eChairperson |
|
| 700 | 1 |
_aNguyen, Thi Kim Oanh, _eExamination Committee |
|
| 700 | 1 |
_aXue, Wenchao, _eExamination committee |
|
| 700 | 0 |
_aTatchai Pussayanavin, _eExamination committee |
|
| 710 | 2 |
_aBangchak Petroleum Public Company Limited, Thailand, _eScholarship Donor |
|
| 710 | 2 |
_aRoyal Thai Government Fellowship, _eScholarship Donor |
|
| 810 | 2 |
_aAsian Institute of Technology. _tThesis ; _vno. EV-21-14 |
|
| 856 |
_3Full-Text _uhttp://203.159.5.9/ait-thesis/detail.php?q=B13496 |
||
| 907 |
_a.b12371993 _bmnait _cm |
||
| 902 | _a240418 | ||
| 998 |
_b0 _c210704 _dm _ea _fm _g0 |
||
| 945 | _lmnait | ||
| 945 | _lmnait | ||
| 945 | _lmnarc | ||
| 945 | _lmnarc | ||
| 942 | _c40 | ||
| 942 | _c67 | ||
| 942 | _c20 | ||
| 909 |
_aBarcode : 30050120885917 _bCREATED : 2021-07-14 _cRECORD # : i13349624 _dLPATRON : 0 _eLCHKIN : - _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 0 _jTOT RENEW : 0 |
||
| 909 |
_aBarcode : - _bCREATED : 2021-07-14 _cRECORD # : i13349636 _dLPATRON : 0 _eLCHKIN : - _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 0 _jTOT RENEW : 0 |
||
| 909 |
_aBarcode : 30050121022049 _bCREATED : 2023-12-01 _cRECORD # : i13424713 _dLPATRON : 0 _eLCHKIN : - _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 0 _jTOT RENEW : 0 |
||
| 909 |
_aBarcode : 30050121022031 _bCREATED : 2023-12-01 _cRECORD # : i13424725 _dLPATRON : 0 _eLCHKIN : - _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 0 _jTOT RENEW : 0 |
||
| 999 |
_c28880 _d28880 |
||