000 04424nas|a2200397 i 4500
005 20260818090724.0
008 280101s2000 th uu m rtt 00| a1eng d
035 _a.b11818852
099 9 _aAIT Thesis no. ET-00-22
100 1 _aRajapakse, Thiromi Renuka
245 1 0 _aDevelopment of a simulation model of an electric arc furnace for harmonic distortion and flicker level estimation
260 _aBangkok :
_bAsian Institute of Technology,
_c2000
300 _a89 leaves
490 1 _aThesis ;
_vno. ET-00-22
500 _aA thesis submitted in partial fulfilment of the requirements for the degree of Master of Engineering
502 _aThesis (M.Eng.) - Asian Institute of Technology
520 _aAmong various power-polluting apparatus, electric arc furnace (EAF) is considered as an exceptional case, since it contributes for multitude of problems such as transients, harmonics, voltage imbalance and voltage flicker. Finding means for mitigation of these undesirable effects requires extensive studies, which are often based on computer simulations. Such studies largely depend on the availability of an accurate simulation model. In this study, a simulation model of an EAF based on the field measurements was developed. The model includes dynamic behavior of the electric arc and stochastic variations in the arc resistance during the initial melting period, which results in worse conditions in terms of voltage flicker and harmonics and was implemented in EMTDC. Accurate representation of electric arc requires modeling of the dynamic behavior of the arc due to nonlinear V -I characteristics as well as the changes in the equivalent arc resistance due to scrap and electrode movements. The changes due to latter ranges from momentary short circuits to open circuits and occur in a random fashion. These random changes were incorporated into classical Cassie arc model as random changes in the arc resistance to derive a realistic representation of the behavior of electric arc furnace. A novel feature of this study is the systematic treatment of this randomly changing part of the arc resistance. Analysis of the frequency spectrums and the auto-correlation functions of the noise samples indicated that the random deviations of arc resistance can be approximately represented by a first order Markov process. The parameters of this first order noise model were estimated from the sample waveforms using standard techniques adopted in signal processmg. Computer simulation of the EAF model and its supply circuit was implemented in EMTDC. Analysis of harmonics of the simulated voltages and currents at different points of the supply system are generally in agreement with field measurements, although one to one comparison is impossible due to the non-characteristic nature. Flicker calculations were performed using an IEC flicker meter simulated in MATLAB SIMULINK environment. Simulated instantaneous flicker level and short duration (2s) PST are in the range of those of the measured waveforms. Further, the simulation model developed was used for investigating the flicker and harmonics levels under the simultaneous operation of two EAFs present in the BSI steel mill. The developed model can be used to study the adverse effects of electric arc furnace operation under various scenarios and options for their mitigation through simulations.
650 1 0 _aElectric furnaces
_xSimulation methods
700 0 _aSurapong Chiraratananon,
_eChairperson
700 1 _aYu, Cun Yi,
_eExamination Committee
700 1 _aRajapakse, Athula,
_eExamination Committee
700 1 _aDhadbanjan, Thukaram,
_eExamination Committee
710 2 _aAsian Institute of Technology,
_eScholarship Donor
810 2 _aAsian Institute of Technology.
_tThesis ;
_vno. ET-00-22
856 _3Full-Text
_uhttp://203.159.5.9/ait-thesis/detail.php?q=B06811
907 _a.b11818852
_bmnait
_cu
902 _a240401
998 _b0
_c010128
_dm
_ea
_fu
_g0
945 _lmnait
945 _lmnarc
942 _c22
942 _c40
909 _aBarcode : 30050120748925
_bCREATED : 2013-11-20
_cRECORD # : i12747348
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 1
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : 30050120347413
_bCREATED : 2016-06-15
_cRECORD # : i13038230
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
999 _c28962