100 0 _aDuong Quoc Hung
245 1 0 _aDistributed generators, reconfiguration and capacitors for loss reduction in primary distribution systems
260 _aPathum Thani, Thailand :
_bAsian Institute of Technology,
_c2008
300 _a157 p. :
_bill. +
_e1 online resource
490 1 _aThesis ;
_vno. ET-08-22
500 _aA thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering in Energy
502 _aThesis (M.Eng.) - Asian Institute of Technology, 2008
520 _aReconfiguration and capacitor placement are major conventional methods for loss reduction in distribution systems. The penetration of distributed generation (DG) into distribution systems has been increasing in many parts of the world due to environment concerns, electricity liberalization, etc. If DG is placed properly, it will be a new and effective method to reduce losses. However, the combination of reconfiguration, DGs and capacitors is considered as one of the latest and most effective methods to minimize losses. Such a combinatorial method is rather complex and can be better solved by some optimization techniques. Firstly, this thesis develops and improves the analytical based method using a novel comprehensive formula to find the optimal size, location and power factor of five types of single DG simultaneously to minimize losses. Secondly, an improved analytical (IA) based method is proposed to place optimal three types of multiple DGs and/or capacitors for loss reduction. Thirdly, an IA based method is also developed to solve optimal reconfiguration with multiple DG and/or capacitor placement. Finally, two loss sensitivity factor (LSF) and the exhaustive load flow (ELF) based methods to place either DGs or capacitors are developed and compared with the IA based method. The methods based on the IA, LSF and ELF techniques have been tested and validated on three test distribution systems. The results show that the IA based method can demand a short computational time as compared with the LSF based method; but it can lead to an optimal or near optimal solution as compared with the ELF based method. The LSF based method may not lead to the best allocation of DGs or capacitors for loss reduction. The IA based method has been applied to a 687-bus practical distribution system of Lam Dong Distribution Department under Power Company No. 2. The results indicate that the proposed method is efficient. When only one DG is considered to optimize the size, location and power factor simultaneously, the loss reduction is significant at 89.68%. When reconfiguration with placing one DG and a capacitor is considered, the loss reduction is better at 94.64%. As the combination of either six DGs and five capacitors or reconfiguration with six DGs and five capacitors, the loss reduction is highest at nearly 99%. However, the loss reduction will be reached at 100%, if the number of DGs is unlimited.
650 0 _aElectric power distribution
650 0 _aPower dissipation
700 1 _aNadarajah, Mithulananthan,
_eChairperson
700 0 _aWeerakorn Ongsakul,
_eExamination Committee
700 1 _aWang, Yaw-Juen,
_eExamination committee
710 2 _aElectricity of Vietnam (EVN),
_eScholarship donor
710 2 _aAsian Institute of Technology Fellowship,
_eScholarship donor
810 2 _aAsian Institute of Technology.
_tThesis ;
_vno. ET-08-22
856 _3Full-Text
_uhttp://203.159.5.9/ait-thesis/detail.php?q=B02190
907 _a.b12045627
_bmnait
_cu
902 _a240401
998 _b0
_c090120
_dm
_ea
_fu
_g0
945 _lmnait
945 _lmnarc
942 _c20
942 _c40
909 _aBarcode : 30050120602437
_bCREATED : 2007-08-23
_cRECORD # : i12589172
_dLPATRON : 1022398
_eLCHKIN : 2010-03-17
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 1
_iTOT CHKOUT : 3
_jTOT RENEW : 1
909 _aBarcode : 30050120368831
_bCREATED : 2016-08-06
_cRECORD # : i13022271
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
999 _c31062
_d31062