| 000 | 03364nam a2200421 4500 | ||
|---|---|---|---|
| 005 | 20260818094245.0 | ||
| 008 | 310798 th eng | ||
| 035 | _a.b10215049 | ||
| 099 | 9 | _aAIT Thesis no.ST-92-12 | |
| 100 | 0 | _aMyint Myint Than | |
| 245 | 1 | 0 | _aDynamic energy dissipation of in-plane reinforced concrete |
| 260 |
_aBangkok : _bAsian Institute of Technology, _c1992 |
||
| 300 | _a86, A-22 leaves | ||
| 490 | 1 |
_aThesis ; _vno. ST-92-12 |
|
| 500 | _aA thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Engineering and Technology | ||
| 502 | _aThesis (M.Eng.) - Asian Institute of Technology, 1992 | ||
| 520 | _aQuantification of damping in cable systems plays an important role in design of modern cable-supported structures. An attempt is made to estimate the damping for a cable-tie sy~tem, which is essentially a special case of a cable system. A method is proposed based on modal damping ratio, which is represented by the ratio of damping energy to potential energy of cabte system. In order to verify the proposed method of damping estimation, a series of experiments is also conducted with a model of cable-tie system. Two different cable-tie systems are studied to show the applicability of proposed method. Free vibration record is used to estimate damping experimentally. The finite element method is employed to calculate dynamic strain amplitude, which is directly associated with potential energy and dissipated energy. Dissipated energy is assumed to be represented in terms of loss factor and strain energy. The loss factor value of single cable is used to estimate dissipated energy of individual cables in the system. The loss factor of cables are obtained by conducting single cable experiment. Results of experimental and proposed analytical method are cohsistent. It is found that the modal damping ratio of the cable-tie system can be evaluated by considering the contribution from individual cables in the system. Proposed method can be used to estimate damping in a cable system analytically. | ||
| 650 | 0 | _aReinforced concrete structures | |
| 650 | 0 | _aEarthquake resistant design | |
| 700 | 1 |
_aMaekawa, Koichi, _eChairperson |
|
| 700 | 1 |
_aYamaguchi, Hiroki, _eExamination committee |
|
| 700 | 0 |
_aKamol Vajarasathira, _eExamination committee |
|
| 710 | 2 |
_aGerman Academic Exchange Service (DAAD), _eScholarship donor |
|
| 810 | 2 |
_aAsian Institute of Technology. _tThesis ; _vno. ST-92-12 |
|
| 856 |
_3Full-Text _u http://203.159.5.9/ait-thesis/detail.php?q=B16910 |
||
| 907 |
_a.b10215049 _bmnait _cs |
||
| 902 | _a240329 | ||
| 998 |
_b2 _c951012 _dm _ea _fs _g0 |
||
| 945 | _lmnait | ||
| 945 | _lmnait | ||
| 945 | _lmnarc | ||
| 942 | _c20 | ||
| 942 | _c40 | ||
| 909 |
_aBarcode : 30050120689350 _bCREATED : 1995-10-13 _cRECORD # : i10260158 _dLPATRON : 0 _eLCHKIN : - _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 0 _jTOT RENEW : 0 |
||
| 909 |
_aBarcode : 30050003065702 _bCREATED : 1995-10-13 _cRECORD # : i1026016x _dLPATRON : 0 _eLCHKIN : - _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 0 _jTOT RENEW : 0 |
||
| 909 |
_aBarcode : 30050160022322 _bCREATED : 2016-04-04 _cRECORD # : i1292278x _dLPATRON : 0 _eLCHKIN : - _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 0 _jTOT RENEW : 0 |
||
| 999 |
_c31946 _d31946 |
||